[1]谭志飞,常昌远,黄建.Nd:YAG激光器横模选择的实验研究[J].东南大学学报(自然科学版),1986,16(4):34-40.[doi:10.3969/j.issn.1001-0505.1986.04.005]
 Tan Zhifei,Chang Changyuan,Huang Jian.Experimental Study ior Transverse Mode Selection of the Nd: YAG Lasers[J].Journal of Southeast University (Natural Science Edition),1986,16(4):34-40.[doi:10.3969/j.issn.1001-0505.1986.04.005]
点击复制

Nd:YAG激光器横模选择的实验研究()
分享到:

《东南大学学报(自然科学版)》[ISSN:1001-0505/CN:32-1178/N]

卷:
16
期数:
1986年第4期
页码:
34-40
栏目:
本刊信息
出版日期:
1986-07-20

文章信息/Info

Title:
Experimental Study ior Transverse Mode Selection of the Nd: YAG Lasers
作者:
谭志飞常昌远黄建
南京工学院电子工程系
Author(s):
Tan Zhifei Chang Changyuan Huang Jian
Department of Electronic Engineering
关键词:
cw Nd: YAG lasers fundamental-transverse mode thermal focal gain factor of small signal resonator for mode selection
Keywords:
cw Nd: YAG lasers fundamental-transverse mode thermal focal gain factor of small signal resonator for mode selection
分类号:
+
DOI:
10.3969/j.issn.1001-0505.1986.04.005
摘要:
本文用简单的方法测量了Nd:YAG棒的热焦距和小信号增益系数;提出了Nd:YAG连续激光器选择基横模的有效设计方法,并对这种选模技术作了实验研究,最后从理论和实验上证实,采用平—平腔加小孔尤阑选择基横模,必须根据热焦距和小信号增益系数正确设计谐振腔参数,否则加小孔光阑是徒劳无益的。
Abstract:
The thermal focal distance of the Nd: YAG rod and the gain factor of small signal are measured by simple methods. An effective design procedure to select fundamental transverse mode for the cw. Nd: YAG lasers is presnted and an experimental study of this technique of transverse mode selection is done. Theory and practice show: if an aperture in the plane-parallel cavity is used to select fundamental transverse mode, the resonator parameters have to be collectly designed. Otherwise it is of no avail, thiat an operture is put into the cavity.