[1]赵延军,陆勇,朱伯友,等.浓相气固两相流质量浓度摩擦电法测量研究[J].东南大学学报(自然科学版),2002,32(6):941-943.[doi:10.3969/j.issn.1001-0505.2002.06.026]
 Zhao Yanjun,Lu Yong,Zhu Boyou,et al.Measuring mass concentration of gas-solid multiphase flow by triboelectricity[J].Journal of Southeast University (Natural Science Edition),2002,32(6):941-943.[doi:10.3969/j.issn.1001-0505.2002.06.026]
点击复制

浓相气固两相流质量浓度摩擦电法测量研究()
分享到:

《东南大学学报(自然科学版)》[ISSN:1001-0505/CN:32-1178/N]

卷:
32
期数:
2002年第6期
页码:
941-943
栏目:
能源与动力工程
出版日期:
2002-11-20

文章信息/Info

Title:
Measuring mass concentration of gas-solid multiphase flow by triboelectricity
作者:
赵延军 陆勇 朱伯友 王式民
东南大学洁净煤发电与燃烧技术教育部重点实验室,南京 210096
Author(s):
Zhao Yanjun Lu Yong Zhu Boyou Wang Shimin
Key Laboratory of Clean Coal Power Generation and Combustion Technology of Ministry of Education, Southeast University, Nanjing 210096, China
关键词:
摩擦电 质量浓度 气固两相流
Keywords:
triboelectricity concentration gas-solid multiphase flow
分类号:
TK313
DOI:
10.3969/j.issn.1001-0505.2002.06.026
摘要:
研究了一种气固两相流质量浓度在线实时检测的测量方法——摩擦电法.推导了固体颗粒与管壁摩擦产生的电流与气固两相流固相质量浓度、气体平均流速以及固相颗粒大小间的关系.以煤粉为研究对象进行实验研究,煤粉质量浓度在17~45 g/m3、气体速度在3~7 m/s范围内,测量段产生的电流和气体流速、颗粒质量流量关系为|Im|=4.92×10-11(-overu)1.77W177,实验数据与理论计算基本符合,误差分析表明其测量误差为20%,从而也验证了摩擦电法的可行性.
Abstract:
The triboelectricity method for on-line real-time measuring mass concentration of the gas-solid multiphase flow is described. The current is produced by the friction between the solid particle and pipe wall, and the relationship between this current and the solid mass concentration of the gas-solid multiphase flow, the average velocity of the gas flow as well as the solid particle size are investigated experimentally. The experiment was carried out by coal powder with a mass concentration of 17-45 g/m3, and the velocity of the gas flow was 3-7 m/s. The relationship of the current, the velocity of the gas flow and the particles mass flux is |Im|=4.92×10-11(-overu)1.77W. The data measured is in accordance with the calculated results. The analysis indicates that the error is no more than 20%. Thus the feasibility is validated.

参考文献/References:

[1] 王式民,徐益谦,陆勇,等.燃煤锅炉排烟粉尘浓度再现检测研究[J].燃烧科学技术,1997,3(1):58-62.
  Wang Shimin,Xu Yiqian,Lu Yong,et al.On-line monitoring particulate mass concentration emitted by coal-fired boiler[J]. Journal of Combustion Science and Technology, 1997,3(1):58-62.(in Chinese)
[2] Li Yan,Yan Dezhong,Su Jiantao,et al.Gas-solid flow measurement at the furnace exit in a tangentially fired boiled[A].In:Xu Yiqian,Zhan Baofen,eds. Development of Measuring Techniques for Multiphase Flows[C].China:Standards Press,1998.94-99.
[3] Hewitt G F. Measurement of two-phase flow parameters[M].London:Academic Press,1978.180-183.
[4] McMurry P H.A review of atmospheric aerosol measurements[J]. Atmos Envir,2000,34:1959-1999.
[5] Murnane S N,Barnes R N,Woodhead S R,et al.Electrostatic modeling and measurement of airborne particle concentration [J]. IEEE Trans Instrum Meas,1996,45:488-492.
[6] Bahar B.New developments in monitoring particulate emissions[J]. American Ceramic Society Bulletin, 1994,73:64-70.
[7] 李海青.两相流参数及其检测[M].杭州:浙江大学出版社,1991.
[8] Masuda H,Komatsu T,Iinoya K.Static electrification of particles in gas-solids pipe flow[J].AICHE Journal,1978,26(3):558-564.
[9] Yan Y,Ma J.Design and evaluation of electrostatic sensor for the measurement of velocity of pneumatically conveyed solids[J]. Flow Measurement and Instrumentation, 2000,11:195-204.

备注/Memo

备注/Memo:
作者简介: 赵延军(1972—),男,博士生; 王式民(联系人),男,教授,博士生导师,smwang@seu.edu.cn.
更新日期/Last Update: 2002-11-20