[1]虞伟,顾宁,武建国,等.两种不同示踪剂用于蛋白质与抗原分子微阵列信号检测的对比研究[J].东南大学学报(自然科学版),2003,33(1):64-67.[doi:10.3969/j.issn.1001-0505.2003.01.016]
 Yu Wei,Gu Ning,Wu Jianguo,et al.Comparative investigation of signal detection for protein and antigen microarray by using two different tracers[J].Journal of Southeast University (Natural Science Edition),2003,33(1):64-67.[doi:10.3969/j.issn.1001-0505.2003.01.016]
点击复制

两种不同示踪剂用于蛋白质与抗原分子微阵列信号检测的对比研究()
分享到:

《东南大学学报(自然科学版)》[ISSN:1001-0505/CN:32-1178/N]

卷:
33
期数:
2003年第1期
页码:
64-67
栏目:
生物医学工程
出版日期:
2003-01-20

文章信息/Info

Title:
Comparative investigation of signal detection for protein and antigen microarray by using two different tracers
作者:
虞伟12 顾宁1 武建国2 葛存旺1 廖建辉1
1 东南大学分子与生物分子电子学教育部重点实验室, 南京 210096; 2 南京军区南京总医院全军医学检验中心临床免疫实验室, 南京 210002
Author(s):
Yu Wei12 Gu Ning1 Wu Jianguo2 Ge Cunwang1 Liao Jianhui1
1 Key Laboratory of Molecular and Bio-molecular Electronics of Ministry of Education, Southeast University, Nanjing 210096, China
2 Laboratory of Clinical Immunology, Center of Medical Laboratory Science, Jinling Hospital of Nanj
关键词:
酶免疫测定法 免疫金银染色法 蛋白质 抗原 微阵列 示踪系统
Keywords:
enzyme immunoassay immunogold-silver staining protein antigen microarray tracer system
分类号:
Q503
DOI:
10.3969/j.issn.1001-0505.2003.01.016
摘要:
以氧化型琼脂糖凝胶膜为基片, 制作蛋白质与抗原分子微阵列, 建立了检测固相人IgG、游离IgG和自身抗体分子的免疫学测定模式,分别以辣根过氧化物酶-二氨基联苯胺-双氧水(HRP-DAB-H2O2)和胶体金-硝酸银-对苯二酚2种示踪系统作为蛋白质与抗原分子微阵列信号显示剂,并对其作用的原理与特点进行讨论.检测结果发现基于胶体金的免疫金银染色法(IGSS)比固相酶免疫测定法(EIA)敏感.2种示踪系统对固相人IgG的最低检出量分别为0.05 ng和0.5 ng; 而对血清游离IgG的最低检出量IGSS法比EIA法至少高出10倍.两法用于自身抗体的测定亦表现出较好的重复性,在14例HCV感染者中,自身抗体的总体检出率分别为38.6%和31.4%,结果具有显著的同步性.故同时辅以2种示踪剂并用于阵列芯片的联合测试,有助于提高自身抗体的总体检出水平.
Abstract:
By using oxidiated agarose-gel membrane as a matrix, protein and antigen microarrays were prepared and subsequent several immunoassays were developed for solid-phase and sample free IgG as well as autoantibodies. In this assay, two display-systems, horseradish peroxidase-diaminobenzidine tetrahydrochloride-hydrogen peroxide(HRP-DAB-H2O2)and colloidal gold-AgNO3-hydroquinone, were utilized as signal detection of microarrays, and also their interaction principles and characteristic which displayed were discussed. The results show that the detective sensitivity of immunogold-silver staining(IGSS)is higher than that of solid-phase enzyme immunoassay(EIA).The minimum solid-phase human IgG limits are 0.05 ng and 0.5 ng respectively. Whereas the lowest serum IgG detected by IGSS is at least 10 times higher than that of EIA. The autoantibodies also show that a good reproducibility is achieved by both methods. The positive rate of autoantibodies in 14 cases with HCV infection are 38.6%(IGSS)and 31.4%(EIA)respectively. The results acquired by using these tracer systems are significantly consistent. Thus the levels of autoantibodies can be improved by using two tracers for microarray detection simultaneously.

参考文献/References:

[1] Lueking A,Horn M,Eickhoff H,et al.Protein microarrays for gene expression and antibody screening[J].Anal Biochem,1999,270(1):103-111.
[2] Borrebaeck C A K.Antibodies in diagnostics-from immunoassays to protein chips[J].Immunol Today,2000,21(8):379-382.
[3] 虞伟,孙永康,顾宁,等.蛋白质与抗体微阵列及其在生物医学研究中的应用[J].生物化学与生物物理进展,2002,19(3):491-494.
  Yu Wei,Sun Yongkang,Gu Ning,et al.Protein and antibody microarrays and their biomedical applications[J].Prog Biochem Biophys,2002,19(3):491-494.(in Chinese)
[4] Zhou H H,Roy S,Schulman H,et al.Solution and chip arrays in protein profiling[J].Trends in Biotechnology,2001,19(10-Suppl):35-39.
[5] 武建国.实用临床免疫学检验[M].南京:江苏科学技术出版社,1990.97,226-268.
[6] Hayat M A.Colloidal gold-principles,methods and application[J]. Academic Press,1989,1:39.
[7] Yu Wei,Gu Ning,Zhang Haiqian,et al.Microarray preparation based on oxidation of agarose-gel and subsequent enzyme immunoassay[A].In:Pacific Rim Workshop on Transducers and Micro/Nano Technologies[C].Xiamen,China:Xiamen University Press,2002.749-752.
[8] 沈关心,周汝麟.现代免疫学实验技术[M].武汉:湖北科学技术出版社,1998.165-168.
[9] Holgate C S.Immunogold-silver staining:new method of immunostaining with enhanced sensitivity[J].J Histochem,1993(7):938.
[10] Kawamoto H,Sakaguchi K,Takaki A,et al.Autoimmune responses as assessed by hypergammaglobulin and the presence of autoantibodies in patients with chronic hepatitis C [J]. Acta Med Okayama,1993,47:305-310.

备注/Memo

备注/Memo:
基金项目: 国家自然科学基金资助项目(60171005).
作者简介: 虞伟(1967—),男,博士生,yuwei@seu.edu.cn; 顾宁(联系人),男, 教授,博士生导师,guning@seu.edu.cn.
更新日期/Last Update: 2003-01-20