[1]王世和,王薇,俞燕.水力条件对人工湿地处理效果的影响[J].东南大学学报(自然科学版),2003,33(3):359-362.[doi:10.3969/j.issn.1001-0505.2003.03.028]
 Wang Shihe,Wang Wei,Yu Yan.Influence of hydraulic condition on treatment effect of constructed wetland[J].Journal of Southeast University (Natural Science Edition),2003,33(3):359-362.[doi:10.3969/j.issn.1001-0505.2003.03.028]
点击复制

水力条件对人工湿地处理效果的影响()
分享到:

《东南大学学报(自然科学版)》[ISSN:1001-0505/CN:32-1178/N]

卷:
33
期数:
2003年第3期
页码:
359-362
栏目:
环境科学与工程
出版日期:
2003-05-20

文章信息/Info

Title:
Influence of hydraulic condition on treatment effect of constructed wetland
作者:
王世和 王薇 俞燕
东南大学环境工程系, 南京 210096
Author(s):
Wang Shihe Wang Wei Yu Yan
Department of Environmental Engineering, Southeast University, Nanjing 210096, China
关键词:
人工湿地 水力条件 运行特性
Keywords:
constructed wetland hydraulic condition operation characteristic
分类号:
X524
DOI:
10.3969/j.issn.1001-0505.2003.03.028
摘要:
在自行建造的人工湿地模型上,通过对污水厂初沉出水的实际处理试验,详细测定并分析了水力负荷、水力停留时间、水深等对人工湿地中SS,COD,NH4+-N,TP去除效果的影响及其规律,探明了各自的净化机理,提出了不同运行条件下的最佳运行参数,从而为人工湿地技术的进一步发展及其工程设计与运行管理提供了参考.
Abstract:
Based on the model of constructed wetland, the treatment experiments on presedimentation effluent of municipal sewage plant were done. The influence and regularity of hydraulic load, hydraulic retention time and water depth on constructed wetland’s SS,COD,NH4+-N,TP removal effect are analyzed in detail, and purification mechanism is explored. Meanwhile, the optimal parameters of different operation condition are proposed so as to provide references for further development, design and operation of constructed wetland.

参考文献/References:

[1] 胡康萍.人工湿地设计中的水力学问题研究[J].环境科学,1991,4(5):8-11.
  Hu Kangping.Hydraulic research in the design of constructed wetland [J].Environmental Science,1991,4(5):8-11.(in Chinese)
[2] Sikora F J.Ammonium removal in constructed wetlands with recirculating subsurface flow:removal rates and mechanisms [J].Wat Sci & Tech,1995,32(3):193-202.
[3] Stober J T.Winter and spring evaluations of a wetlands of tertiary wastewater treatment [J]. Wat Environ Res,1997,69(5):961-968.
[4] Platzer Christoph.Design recommendations for subsurface flow constructed wetlands for nitrification and denitrification [J].Wat Sci & Tech,1999,40(3):257-263.
[5] 卢学强.污水湿地处理工程水力停留时间的测定[J].干旱环境监测,1999,13(2):74-75.
  Lu Xueqiang.HRT measurement of wetland project for wastewater treatment[J].Arid Environmental Monitoring,1999,13(2):74-75.(in Chinese)

相似文献/References:

[1]刘慎坦,王国芳,谢祥峰,等.不同基质对人工湿地脱氮效果和硝化及反硝化细菌分布的影响[J].东南大学学报(自然科学版),2011,41(2):400.[doi:10.3969/j.issn.1001-0505.2011.02.035]
 Liu Shentan,Wang Guofang,Xie Xiangfeng,et al.Effect of matrix on denitrification efficiency and distribution of nitrifying and denitrifying bacteria in constructed wetlands[J].Journal of Southeast University (Natural Science Edition),2011,41(3):400.[doi:10.3969/j.issn.1001-0505.2011.02.035]
[2]黄娟,杨思思,郭杨,等.强化供氧对低温域人工湿地脱氮及微环境的影响[J].东南大学学报(自然科学版),2013,43(5):1000.[doi:10.3969/j.issn.1001-0505.2013.05.017]
 Huang Juan,Yang Sisi,Guo Yang,et al.Influence of aeration on nitrogen removal effect and microenvironment in constructed wetland at low temperature[J].Journal of Southeast University (Natural Science Edition),2013,43(3):1000.[doi:10.3969/j.issn.1001-0505.2013.05.017]

备注/Memo

备注/Memo:
基金项目: 江苏省建设厅科研基金资助项目(JS9910).
作者简介: 王世和(1945—), 男, 硕士, 教授, 博士生导师, wshhj@seu.edu.cn.
更新日期/Last Update: 2003-05-20