[1]周强泰,赵伶玲,王泽宁,等.螺旋槽管强化传热研究及其在锅炉中的应用[J].东南大学学报(自然科学版),2005,35(1):1-6.[doi:10.3969/j.issn.1001-0505.2005.01.001]
 Zhou Qiangtai,Zhao Lingling,Wang Zening,et al.Studies on heat transfer enhancement of spirally corrugated tube and its application to boilers[J].Journal of Southeast University (Natural Science Edition),2005,35(1):1-6.[doi:10.3969/j.issn.1001-0505.2005.01.001]
点击复制

螺旋槽管强化传热研究及其在锅炉中的应用()
分享到:

《东南大学学报(自然科学版)》[ISSN:1001-0505/CN:32-1178/N]

卷:
35
期数:
2005年第1期
页码:
1-6
栏目:
能源与动力工程
出版日期:
2005-01-20

文章信息/Info

Title:
Studies on heat transfer enhancement of spirally corrugated tube and its application to boilers
作者:
周强泰 赵伶玲 王泽宁 陆国栋
东南大学动力工程系, 南京 210096
Author(s):
Zhou Qiangtai Zhao Lingling Wang Zening Lu Guodong
Department of Power Engineering, Southeast University, Nanjing 210096, China
关键词:
螺旋槽管 传热研究 电站煤粉锅炉 空气预热器
Keywords:
spirally corrugated tube heat transfer research pulverized coal power plant boilers air preheater
分类号:
TK223.34
DOI:
10.3969/j.issn.1001-0505.2005.01.001
摘要:
论述了螺旋槽管管内外单相流体传热研究的试验结果,并将试验数据按流动参数、物性参数和几何参数采用无量纲准则数进行整理.给出了在雷诺数Rei=10441055范围内管内无量纲换热系数Nui的关联式,和在Reo=3×10336×1044及Reo=3.3×10331055范围内气流横掠螺旋槽管错列和顺列管束的管外无量纲换热系数Nuo的关联式,该关联式可以作为螺旋槽管换热器的设计依据.介绍了螺旋槽管作为空气预热器在电站煤粉锅炉中的广泛应用,给出了几个应用螺旋槽管空气预热器解决锅炉具体问题的实例,表明了螺旋槽管空气预热器的显著优越性.
Abstract:
In order to achieve heat transfer enhancement of heat exchangers with tube types to save energy, the experimental studies on heat transfer of single-phase fluid for spirally corrugated tubes with tube side and cross flow are presented. The heat transfer data are nondimensionalized to form several dimensionless numbers with the parameters of fluid flow, physical properties of fluid and geometries of tubes. The correlation of tube-side heat transfer dimensionless coefficient Nui of spirally corrugated tubes in Reynolds numbers Rei=104-105,the correlation of the cross-flow heat transfer dimensionless coefficient Nuo for staggered arrangement in Reo=3×103-6×104 and for the in-line arrangement in Reo=3.3×103-105 of spirally corrugated tube banks are presented respectively, which can be used to design the heat exchangers with spirally corrugated tube. The widely application of spirally corrugated tube to the air preheater for pulverized coal fired boilers in power plant is introduced, and several practical uses of the spirally corrugated tube air preheater to solve the existing problems for boilers are given. It is shown that the air preheater with spirally corrugated tube has obvious advantages over other types of air preheater.

参考文献/References:

[1] Sethumadavam R,Rao M R.Turbulent flow friction and heat transfer characteristics of single and multi-start spirally enhanced tubes [J].J of Heat Transfer, 1986,108(2):56-61.
[2] Zhou Qiangtai,Zhang Zixin,Ye Saiyin,et al.Heat transfer of gas flow inside spirally corrugated tubes[A].In:Deng Songjiu,ed.Heat Transfer Enhancement and Engergy Conservation[C].New York:Hemisphere Publishing Corporation,1990.105-111.
[3] Zimparov V D,Vulchanov N L,Delov L B.Heat transfer and friction characteristics of spirally corrugated tubes for power plant condensers — 1.Experimental investigation and performance evaluation[J]. Int J Heat Mass Transfer, 1990,34(9):2187-2197.
[4] Watkinson A P.Fouling of augmented heat transfer tubes [J].Heat Transfer Engineering, 1990,11(3):57-65.
[5] 叶赛银.螺旋槽管强化管内外单相流体传热的研究[D].南京:东南大学动力工程系,1987.
[6] 张华.管内强化传热研究[D].南京:东南大学动力工程系,1995.
[7] 王泽宁.管内单相流体复合强化传热研究[D].南京:东南大学动力工程系,2004.
[8] 李建峰.螺旋槽管束传热及阻力特性研究[D].南京:东南大学动力工程系,1991.
[9] 陆国栋.顺列螺旋槽管传热及光管颗粒撞击特性研究[D].南京:东南大学动力工程系,2004.
[10] Zhou Q T, Gu N Z,Ye S Y.New techniques of heat transfer enhancement in boilers[A].In: ASME Paper[C].New York,1991.1-5.
[11] 周强泰, 叶赛银,王泽宁.高效节能螺旋槽管空气预热器[J].电力技术,1992(9):12-14.
  Zhou Qiangtai,Ye Saiyin,Wang Zening.High-efficient energy-saving air preheater with spirally corrugated tubes[J].Electric Power Technology,1992(9):12-14.(in Chinese)
[12] 永济热电厂, 山西省电力试验研究所.永济热电厂3号炉低温级省煤器、低温级空气预热器改造鉴定试验报告[R].山西:永济热电厂,1996.
[13] 胡志坚, 龚斌奇.贵溪电厂3号炉改装螺旋槽管空气预热器后节能效果分析[J].江西电力,1997(1):28-30.
  Hu Zhijian,Gong Binqi.Energy-saving analysis with retrofit of spirally corrugated tube air preheater for No.3 boiler of Guixi Power Plant[J].Jiangxi Electric Power, 1997(1):28-30.(in Chinese)
[14] 黄岛发电厂.1号炉大修后效率试验报告[R].青岛:黄岛发电厂,2003.

备注/Memo

备注/Memo:
作者简介: 周强泰(1935—),男,教授,博士生导师.