[1]杜垲,张卫红.转轮与冷却除湿组合式空调系统变工况稳态性能模拟分析[J].东南大学学报(自然科学版),2005,35(1):86-89.[doi:10.3969/j.issn.1001-0505.2005.01.019]
 Du Kai,Zhang Weihong.Simulation and analysis of steady-state behavior under variable work conditions of DWCCDS[J].Journal of Southeast University (Natural Science Edition),2005,35(1):86-89.[doi:10.3969/j.issn.1001-0505.2005.01.019]
点击复制

转轮与冷却除湿组合式空调系统变工况稳态性能模拟分析()
分享到:

《东南大学学报(自然科学版)》[ISSN:1001-0505/CN:32-1178/N]

卷:
35
期数:
2005年第1期
页码:
86-89
栏目:
能源与动力工程
出版日期:
2005-01-20

文章信息/Info

Title:
Simulation and analysis of steady-state behavior under variable work conditions of DWCCDS
作者:
杜垲 张卫红
东南大学动力工程系, 南京 210096
Author(s):
Du Kai Zhang Weihong
Department of Power Engineering, Southeast University, Nanjing 210096, China
关键词:
转轮 除湿 组合 模拟分析
Keywords:
desiccant wheel dehumidification combined simulation and analysis
分类号:
TU83;TK12
DOI:
10.3969/j.issn.1001-0505.2005.01.019
摘要:
建立了转轮和冷却除湿组合式空调系统(DWCCDS)的数学模型,分析了DWCCDS与压缩式冷却除湿系统的特性,并对两者除湿过程做了对比.用所建立的模型对DWCCDS进行了变工况稳态性能模拟,得出室外空气温度、室外空气含湿量、处理空气送风量对DWCCDS影响的相关规律,同时也说明了在低湿环境的条件下,采用DWCCDS具有很好的优越性,为该系统的进一步研究及优化运行提供参考.
Abstract:
The mathematic model of desiccant wheel combined with cooling dehumidification air conditioning system(DWCCDS)is established. The characteristic analysis of DWCCDS and the compression one is done, meanwhile a comparison between these two dehumidification process is made. Simulation of the steady-state behavior under variable work conditions of DWCCDS in terms of the mathematics model was conducted. Correlative rules of the dehumidification system, which are influenced by the temperature of outdoor air, the wet quantity of outdoor air and the wind amount of disposed air are obtained. All of these prove the superiority of adopting DWCCDS under low wet of environment, and offer a reference for further study on this system.

参考文献/References:

[1] Zhang L Z, Niu J L.Performance comparisons of desiccant wheels for air dehumidification and enthalpyrecovery[J].Applied Thermal Engineering,2002,22(12):1347-1367.
[2] 薛殿华.空气调节[M].北京:清华大学出版社,1991.185-193.
[3] 袁卫星. 开式固体除湿空调关键部件及系统分析 [J].北京航空航天大学学报,1997,23(5):596-601.
  Yuan Weixing.Analysis of open-cycle solid desiccant air conditioning system and its key component-dehumidifier[J].Journal of Beijing University of Aeronautics and Astronautics, 1997,23(5):596-601.(in Chinese)
[4] 代彦军,俞金娣.转轮式干燥冷却系统的参数分析与性能预测 [J].太阳能学报,1998,19(1):60-65.
  Dai Yanjun,Yu Jindi.Parametric analysis and performance prediction of desiccant cooling system[J].Acta Energiae Solaris Sinica, 1998,19(1):60-65.(in Chinese)
[5] 秦朝葵, Schmitz Gerhard.氯化锂除湿转轮的性能预测[J].同济大学学报,2002,30(7):807-810.
  Qin Chaokui,Schmitz Gerhard.Performance prediction of LiCl rotary dehumidifier[J].Journal of Tongji University, 2002,30(7):807-810.(in Chinese)
[6] Niu J L, Zhang L Z,Zuo H G.Energy saving potential of chilled-ceiling combined with desiccant cooling in hot and humid climates [J].Energy and Buildings,2002,34(5):487-495.
[7] San J Y, Jiang G D.Modeling and testing of a silica gel packed-bed system [J].Int J of Heat and Mass Transfer, 1994,37(8):1137-1179.
[8] Dai Y J, Wang R Z,Zhang H F.Parameter analysis to improve rotary desiccant dehumidification using a mathematical model[J].International Journal of Thermal Sciences, 2001,40(4):400-408.
[9] 张卫红. 转轮与冷却组合式除湿空调系统变工况稳态性能模拟与分析[D].南京:东南大学动力工程系,2001.

相似文献/References:

[1]李秀伟,张小松,程清,等.光伏/光热驱动的溶液除湿空调系统性能比较[J].东南大学学报(自然科学版),2014,44(2):295.[doi:10.3969/j.issn.1001-0505.2014.02.013]
 Li Xiuwei,Zhang Xiaosong,Cheng Qing,et al.Performance comparison between photovoltaic and solar thermal driven liquid dehumidification air-conditioning system[J].Journal of Southeast University (Natural Science Edition),2014,44(1):295.[doi:10.3969/j.issn.1001-0505.2014.02.013]

备注/Memo

备注/Memo:
基金项目: 国家自然科学基金资助项目(50476045).
作者简介: 杜垲(1955—),男,教授,du-kai@seu.edu.cn.