[1]王跃轩,易红,倪中华,等.医用血管支架生物力学性能分析方法研究[J].东南大学学报(自然科学版),2005,35(2):216-221.[doi:10.3969/j.issn.1001-0505.2005.02.012]
 Wang Yuexuan,Yi Hong,Ni Zhonghua,et al.Research on biomechanical characteristic of medical vascular stent[J].Journal of Southeast University (Natural Science Edition),2005,35(2):216-221.[doi:10.3969/j.issn.1001-0505.2005.02.012]
点击复制

医用血管支架生物力学性能分析方法研究()
分享到:

《东南大学学报(自然科学版)》[ISSN:1001-0505/CN:32-1178/N]

卷:
35
期数:
2005年第2期
页码:
216-221
栏目:
计算机科学与工程
出版日期:
2005-03-20

文章信息/Info

Title:
Research on biomechanical characteristic of medical vascular stent
作者:
王跃轩 易红 倪中华 顾兴中
东南大学机械工程系, 南京 210096
Author(s):
Wang Yuexuan Yi Hong Ni Zhonghua Gu Xingzhong
Department of Mechanical Engineering, Southeast University, Nanjing 210096, China
关键词:
医用血管支架 支架生命周期 体外扩张 非线性有限元
Keywords:
medical vascular stent stent life cycle in vitro expansion nonlinear finite element
分类号:
TP391.9
DOI:
10.3969/j.issn.1001-0505.2005.02.012
摘要:
介绍了医用血管支架的应用背景和研究现状,在比较国内外研究成果的基础上,将血管支架生命周期划分为设计与制造、支架扩张植入过程和植入后有效期3个阶段,并对各个阶段的特点进行了详细论述; 阐述了在支架生命周期中应用有限元技术进行支架设计的研究思路; 针对支架植入时的扩张过程进行实例分析,例证了应用有限元法进行支架设计研究的分析方法; 提出了支架体外扩张实验研究的解决方案,为血管支架扩张过程的有限元模拟提供有力的实验支持.
Abstract:
The application background and research overview of medical vascular stent are presented. Based on the comparison of domestic and foreign research achievements, the life cycle of medical vascular stent is divided into three phases, i.e., design and manufacture, stent expansion process and long-term in vivo service. The characteristics of each phase in the life cycle are specified. The research idea of designing stent by finite element method in the whole life cycle is expatiated. An example of analyzing stent expansion is presented to exemplify the application of the finite element method to the stent design. The experimental solution of in vitro stent expansion is also proposed. The scheme proposed in this paper provides powerful experimental support for the simulation of stent expansion process through finite element method.

参考文献/References:

[1] Chua S N D,MacDonald B J,Hashmi M S J.Finite-element simulation of stent expansion [J].Materials Processing Technology, 2002,120:335-340.
[2] Chua S N D,MacDonald B J,Hashmi M S J.Finite element simulation of stent and balloon interaction [J]. Materials Processing Technology, 2003,143-144:591-597.
[3] Migliavacca F,Petrini L,Colombo M.Mechanical behavior of coronary stents investigated through the finite element method [J]. Journal of Biomechanics, 2002,35(6):803-811.
[4] Petrini L,Migliavacca F,Auricchio F,et al.Numerical investigation of the intravascular coronary stent flexibility [J]. Journal of Biomechanics, 2004,37(4):495-501.
[5] Dumoulin C,Cochelin B.Mechanical behavior modeling of balloon-expandable stents [J].Journal of Biomechanics,2000,33(11):1461-1470.
[6] Squire J C.Dynamics of endovascularstent expansion [D].Cambridge,MA:Massachusetts Institute of Technology,2000.
[7] Perktold K.Three-dimensional numerical analysis of pulsatile flow and wall shear stress in the carotid artery bifurcation [J].Journal of Biomechanics,24(6):409-420.
[8] Perktold K,Rappitsch G.Computer simulation of local blood flow and vessel mechanics in a compliant carotid artery bifurcation model [J].Journal of Biomechanics, 1995,28(7):845-856.
[9] Natarajan S,Mokhtarzadeh-Dehghan M R.A numerical and experimental study of periodic flow in a model of a corrugated vessel with application to stented arteries [J].Medical Engineering & Physics, 2000,22:555-566.
[10] Etave F,Finet G,Boivina M.Mechanical properties of coronary stents determined by using finite element analysis [J].Journal of Biomechanics, 2001,34:1065-1075.
[11] Wentzel J J,Whelan D M,van der Giessen W J.Coronary stent implantation changes 3-D vessel geometry and 3-D shear stress distribution [J].Journal of Biomechanics,2000,33(10):1287-1295.
[12] Milner J S,Moore J A,Rutt B K,et al.Hemodynamics of human carotid artery bifurcations:computational studies with models reconstructed from magnetic resonance imaging of normal subjects [J].Journal of Vascular Surgery, 1998,28:143-156.
[13] Moore J A,Steinman D A,Ethier C R.Computational blood flow modeling:errors associated with reconstructing finite element models from MRI [J].Journal of Biomechanics, 1998,31:179-184.
[14] Taylor C A,Hughes T J R,Zarins C K.Finite element modeling of blood flow in arteries [J].Computer Methods in Applied Mechanics and Engineering, 1998,158(1,2):155-196.

备注/Memo

备注/Memo:
基金项目: 国家自然科学基金资助项目(50475074).
作者简介: 王跃轩(1977—),男,博士生,wangyx100@163.com; 易红(联系人),男,博士,教授,博士生导师, yihong@seu.edu.cn.