[1]顾兴中,易红,倪中华,等.冠状动脉支架的设计与加工工艺[J].东南大学学报(自然科学版),2005,35(6):898-902.[doi:10.3969/j.issn.1001-0505.2005.06.015]
 Gu Xingzhong,Yi Hong,Ni Zhonghua,et al.Design and fabrication of coronary stent[J].Journal of Southeast University (Natural Science Edition),2005,35(6):898-902.[doi:10.3969/j.issn.1001-0505.2005.06.015]
点击复制

冠状动脉支架的设计与加工工艺()
分享到:

《东南大学学报(自然科学版)》[ISSN:1001-0505/CN:32-1178/N]

卷:
35
期数:
2005年第6期
页码:
898-902
栏目:
机械工程
出版日期:
2005-11-20

文章信息/Info

Title:
Design and fabrication of coronary stent
作者:
顾兴中 易红 倪中华 王跃轩
东南大学机械工程系, 南京 210096
Author(s):
Gu Xingzhong Yi Hong Ni Zhonghua Wang Yuexuan
Department of Mechanical Engineering, Southeast University, Nanjing 210096, China
关键词:
冠状动脉支架 制作工艺 激光切割 真空退火 电化学抛光
Keywords:
coronary stent process of fabricating laser cutting vacuum annealing electro-polishing
分类号:
TH122;TH162.1
DOI:
10.3969/j.issn.1001-0505.2005.06.015
摘要:
提出了面向激光雕刻管状冠状动脉支架的通用化制作工艺流程,包括支架的结构设计、材料选择、切割、真空退火和电化学抛光等关键工序.研究了金属覆盖率、网孔、轴向短缩率和支撑效率等的相互影响, 以选择合理的支撑环和连杆形式; 确定了激光切割加工中最优化切割路径和机器参数; 阐述了抛光前处理时酸洗液的选择、酸洗温度和时间的控制,以及真空退火时升温速度、冷却速度和保温时间的控制; 分析了抛光液的选择和电极设计,以及抛光温度、电压和时间对电化学抛光效果的影响; 并设计制作出了符合体外测试要求的支架样件.
Abstract:
The general process of fabrication oriented to the laser cutting tubular coronary stent is presented. The key procedures comprise stent configuration, material selection, laser cutting, vacuum annealing and electro-polishing. The metal coverage, cell window, axial shortening, support efficiency and their interactions are investigated to design the proper supporting struts and linking rings. The optimized cutting path and parameters of cutting machine are put forward. The selection of pickling solution, time and temperature are expatiated, and the control of heat preservation, heating and cooling speed for vacuum annealing are studied. After analyzing the electrolyte selection and electrode design, the influence of voltage, time and temperature in electro-polishing is discussed. Some stents were produced with good performance, which were validated by testing in vitro. The research results provide technical support for fabricating metal stent with excellent biomechanics properties.

参考文献/References:

[1] Stoeckel D,Bonsignore C,Duda S.A survey of stent designs[J].Min Invas Ther & Allied Technol,2002,11(4):137-147.
[2] Henry M,Klonaris C,Amor M,et al.State of the art:which stent for which lesion in peripheral interventions? [J]. Tex Heart Inst J,2000,27(2):119-126.
[3] McClean D R,Eigler N L.Stent design:implications for restenosis [J].Rev Cardiovasc Med,2002,3(suppl.5):16-22.
[4] Rogers C D K.Drug-eluting stents:role of stent design,delivery vehicle,and drug selection[J]. Rev Cardiovasc Med,2002,3(suppl.5):10-15.
[5] Raval A,Choubey A,Engineer C,et al.Development and assessment of 316LVM cardiovascular stents [J]. Materials Science and Engineering A,2004,386:331- 343.
[6] Kathuria Y P.Laser microfabrication of biocompatible metallic stent for medical therapy [A].In:Steiner R W,ed.Proceedings of SPIE-OSA Biomedical Optics [C].Japan,2003.SPIE 5142:176-186.
[7] 黄 远,李林安,刘文西.医用心血管支架的非线性有限元分析[J].中国生物医学工程学报,2003,22(2):139-148.
  Huan Yuan,Li Linan,Liu Wenxi.The nonlinear finite elements analysis of the blood vessel stent [J].Chinese Journal of Biomedical Engineering,2003,22(2):139-148.(in Chinese)
[8] Poncin P,Proft J.Stent tubing:understanding the desired attributes [A].In:Shrivastava S,ed. Proceedings from the Materials & Processes for Medical Devices Conference[C].Anaheim:ASM International,2003.253-259.
[9] Veiko V P.Laser microshaping:fundamentals,practical applications,and future prospects [J].RIKEN Review,2001,32:11-18.
[10] Zhao H,Humbeeck J V,Sohier J,et al.Electrochemical polishing of 316L stainless steel slotted tube coronary stents [J]. Journal of Materials Science:Materials in Medicine,2002,13:911-916.
[11] Balcon R,Beyar R,Chierchia S,et al.Recommendations on stent manufacture,implantation and utilization [J]. European Heart Journal, 1997,18:1536-1547.
[12] U.S.Department of Health and Human Services Food and Drug Administration.Guidance for industry and FDA staff.non-clinical tests and recommended labeling for intravascular stents and associated delivery systems [EB/OL].http://www.fda.gov/cdrh/ode/guidance/1545.pdf.2005-07-09.

备注/Memo

备注/Memo:
基金项目: 国家自然科学基金资助项目(50475074).
作者简介: 顾兴中(1971—),男,博士生; 易 红(联系人),男,博士,教授,博士生导师,yihong@seu.edu.cn.
更新日期/Last Update: 2005-11-20