Title:
Development of alternating magnetic field intensity measurement setup for cancer therapy
作者:
汪长岭 徐睿智 顾宁
东南大学生物电子学国家重点实验室, 南京 210096; 东南大学江苏省生物材料与器件重点实验室, 南京 210009
Author(s):
Wang Changling Xu Ruizhi Gu Ning
State Key Laboratory of Bioelectronics, Southeast University, Nanjing 210096, China
Jiangsu Key Laboratory for Biomaterials and Devices, Southeast University, Nanjing 210009, China
关键词:
肿瘤热疗 磁性纳米颗粒 磁场测量 DSP
Keywords:
cancer therapy magnetic nanoparticles alternating magnetic field measurement DSP(digital signal processing)
分类号:
TP391.76
DOI:
10.3969/j.issn.1001-0505.2009.04.028
摘要:
为了得到热疗用交变磁场场强的空间分布,设计并研制了基于DSP的磁场测量装置.该装置由3个部分构成:交变磁场传感器、感应电压信号处理采集模块和线圈传感器的三轴运动导轨.交变磁场传感器由面积很小的单匝线圈构成,相对较大的磁场分布空间,通过小线圈的磁场可近似视为均匀.线圈测得的磁场信号经过前端处理转化为数字信号.通过三轴运动导轨控制传感器的位置可以得到空间各点的磁场强度信号.由于DSP F2812具有良好的运动控制功能以及片载A/D较高采样的频率,可用来控制整个系统.根据磁场强度的分布可以确定热疗中升温效果最好的空间.
Abstract:
In order to measure the distribution of alternating magnetic field intensity,the alternating magnetic field intensity measurement setup based on DSP(digital signal processing)was designed. It is made up of three parts, field sensor, signal processing and collection system, and three-axis motion system. The sensor is a small loop where the magnetic field can be considered uniform in respect to the larger area of alternating magnetic field. The signals from sensor are converted into digital signals for the sequent processing. The spatial distribution of field intensity can be obtained by moving the sensor with the three-axis motion system. DSP F2812 is chosen as the central control unit due to its good capability of controlling motion as well as the relatively high sampling frequency of the A/D convertor. By the measurement of magnetic field distribution with this equipment, the optimal field area for hyperthermia can be found out, providing a good referring factor for clinicians in the magnetic fluid hyperthermia(MFH)cancer therapy.

参考文献/References:

[1] Jordan A,Scholz R,Maier-Hauff K,et al.Presentation of a new magnetic field therapy system for the treatment of human solid tumors with magnetic fluid hyperthermia[J]. Journal of Magnetism and Magnetic Materials,2001,225(1/2):118-126.
[2] Jordan A,Scholz R,Wust P,et al.Magnetic fluid hyperthermia(MFH):cancer treatment with AC magnetic field induced excitation of biocompatible superparamagnetic nanoparticles [J]. Journal of Magnetism and Magnetic Materials,1999,201(1/2/3):413-419.
[3] Xu R Z,Zhang Y,Ma M,et al.Measurement of specific absorption rate and thermal simulation for arterial embolization hyperthermia in the Maghemite-Gelled model[J].IEEE Transactions on Magnetics,2007,43(3):1078-1085.
[4] 潘启军,马伟明,赵治华,等.磁场测量方法的发展及应用[J].电工技术学报,2005,20(3):7-13.
  Pan Qijun,Ma Weiming,Zhao Zhihua,et al.Development and application of measurement method for magnetic field[J]. Transactions of China Electrotechnical Society,2005,20(3):7-13.(in Chinese)
[5] Texas Instruments Inc.SPRS174O MS320F2810,TMS320F2811,TMS320F2812,TMS320C2810,TMS320C2811,TMS320C2812 Digital signal processors data manual[EB/OL].(2007)[2008-04-02].http://focus.ti.com/lit/ds/symlink/tms320f2812.pdf.
[6] Texas Instruments Inc.SPRU060B TMS320F28x DSP Analog-to-digital converter(ADC)reference guide[EB/OL].(2004-06)[2008-04-02].http://stag.zcu.cz/fel/kev/mrp/texas/ADC%20spru060b.pdf.
[7] Pennes H H.Analysis of tissue and arterial temperature in the resting human forearm[J].Journal of Applied Physiology,1948,1(2):93-122.
[8] Rosensweig R E.Heating magnetic fluid with alternating magnetic field[J]. Journal of Magnetism and Magnetic Materials,2002,252(1/2/3):370-374.
[9] Pankhurst Q A,Connolly J,Jones S K,et al.Application of magnetic nanoparticles in biomedicine[J].Journal of Physics D:Applied Physics,2003,36(13):167-181.

备注/Memo

备注/Memo:
作者简介: 汪长岭(1983—),男,博士生; 顾宁(联系人),男,博士,教授,博士生导师,guning@seu.edu.cn.
基金项目: 国家重大科学研究计划资助项目(2006CB933206)、国家自然科学基金重点资助项目(90406023).
引文格式: 汪长岭,徐睿智,顾宁.肿瘤热疗交变磁场中场强分布测量装置[J].东南大学学报:自然科学版,2009,39(4):795-798.[doi:10.3969/j.issn.1001-0505.2009.04.028]
更新日期/Last Update: 2009-07-20