[1]张普,朱虹,孟少平,等.混杂FRP-混凝土T形组合梁受弯性能试验研究[J].东南大学学报(自然科学版),2010,40(3):548-553.[doi:10.3969/j.issn.1001-0505.2010.03.022]
 Zhang Pu,Zhu Hong,Meng Shaoping,et al.Experimental study on bending performances of hybrid FRP-concrete composite T-beams[J].Journal of Southeast University (Natural Science Edition),2010,40(3):548-553.[doi:10.3969/j.issn.1001-0505.2010.03.022]
点击复制

混杂FRP-混凝土T形组合梁受弯性能试验研究()
分享到:

《东南大学学报(自然科学版)》[ISSN:1001-0505/CN:32-1178/N]

卷:
40
期数:
2010年第3期
页码:
548-553
栏目:
土木工程
出版日期:
2010-05-20

文章信息/Info

Title:
Experimental study on bending performances of hybrid FRP-concrete composite T-beams
作者:
张普12 朱虹12 孟少平12 雷云12 吴刚12 吴智深2
1 东南大学混凝土及预应力混凝土结构教育部重点实验室,南京 210096; 2 东南大学城市工程科学国际研究中心, 南京 210096
Author(s):
Zhang Pu12 Zhu Hong12 Meng Shaoping12 Lei Yun12 Wu Gang12 Wu Zhishen2
1 Key Laboratory of Concrete and Prestressed Concrete Structures of Ministry of Education, Southeast University, Nanjing 210096, China
2 International Institute for Urban Systems Engineering, Southeast University, Nanjing 210096, China
关键词:
FRP-混凝土组合梁 受弯性能 湿黏结 界面方式 混杂效应
Keywords:
FRP-concrete composite beams bending performance wet-bond interface mode hybrid effect
分类号:
TU398.9
DOI:
10.3969/j.issn.1001-0505.2010.03.022
摘要:
设计并研究了一种耐久性较好的混杂纤维-混凝土(HFRP-RC)组合梁.通过12根四点受弯T形梁的试验研究,分析了湿黏结等界面方式的可靠性以及HFRP-RC组合梁的性能.试验结果表明,HFRP-RC组合梁在钢筋屈服后具有明显的二次刚度,有较高的极限承载力和较好的位移延性.试验中所有使用C50混凝土组合梁的破坏模式均为梁底部纤维拉断,表明外贴FRP界面(干黏结)、直接在FRP模壳上刷胶然后浇筑混凝土界面(湿黏结)以及在FRP模壳上预黏石子形成的界面都获得了较好的黏结性能.将碳纤维(CFRP)与玄武岩纤维(BFRP)进行混杂,可以提高CFRP的极限应变值,且BFRP比例越高,提高越明显,因此计算临界混杂比和HFRP-RC组合梁极限承载力时,应考虑CFRP极限应变提高系数.
Abstract:
A type of hybrid fiber reinforced polymer-concrete(HFRP-RC)composite beams with high durability is designed and researched. 12 pieces of 4-point bending experiments of T-shaped beams are carried out to further study the reliability of the wet-bonding and the performances of the HFRP-RC composite beams. After the yielding of the steel bars, the HFRP-RC composite beams still have secondary stiffness, high bearing capacity and good displacement ductility. The failure modes of all of the C50 beams are fiber fracture, showing that good bond behaviors can be achieved by externally bonding the FRP onto the precast concrete(referred to as dry-bond), by applying adhesive to the FRP shuttering before the fresh concrete is cast(referred to as wet-bond), and by coating gravel on the inside surface of the FRP shuttering before the fresh concrete is placed in position. Hybridizing the basalt fiber reinforced polymer(BFRP)with the carbon fiber reinforced polymer(CFRP)can improve the ultimate strain of the latter. And the higher the ratio of the BFRP is, the higher the ultimate strain of the CFRP is. Therefore, the improvement factor of the ultimate strain value of the CFRP should be introduced when calculating the critical mixing ratio and the theoretical capacity load values of the HFRP-RC composite beams.

参考文献/References:

[1] 郝庆多,王勃,欧进萍.纤维增强塑料筋在土木工程中的应用[J].混凝土,2006(9):38-44.
  Hao Qingduo,Wang Bo,Ou Jinping.Fiber reinforced polymer rebar’s application to civil engineering[J]. Concrete,2006(9):38-44.(in Chinese)
[2] Wu Zhishen,Bi Wenxiao,Sakuma N.Innovative externally bonded FRP-concrete hybrid flexural members[J].Composite Structures,2006,72(3):289-300.
[3] Shao Y,Wu Z S,Bian J.Wet-bonding between FRP laminates and cast-in-place concrete[C] //International Symposium on Bond Behavior of FRP in Structures.Hong Kong,China,2005:91-96.
[4] 田小岩.HFRP及其与现浇混凝土黏结力学性能研究[D].郑州:郑州大学土木工程学院,2007.
[5] Canning L,Hollaway L,Thorne A M.An investigation of the composite action of an FRP/concrete prismatic beam[J].Construction and Building Materials,1999,13(8):417-426.
[6] Deskovic N,Triantafillou T C,Meier U.Innovative design of FRP combined with concrete:short-term behavior[J]. Journal of Structural Engineering,ASCE,1995,121(7):1069-1078.
[7] Hulatt J,Hollaway L,Thorne A.Short term testing of hybrid T beam made of new prepares material [J]. Journal of Composites for Construction,2003,7(2):135-144.
[8] 张志春.结构新型热固性FRP复合筋及其性能[D].哈尔滨:哈尔滨工业大学土木工程学院,2008.
[9] 孔琴.碳纤维布加固钢筋混凝土梁受弯性能的试验研究[J].郑州大学学报:工学报,2004,25(4):24-27.
  Kong Qin.Experimental investigation of RC beam strengthened with CFRP [J]. Journal of Zhengzhou University:Engineering Science,2004,25(4):24-27.(in Chinese)
[10] 李贵炳,张爱晖,金伟良.钢筋混凝土梁加固时的既有荷载对其抗弯性能的影响[J].土木工程学报,2006,39(1):13-20.
  Li Guibing,Zhang Aihui,Jin Weiliang.Effect of sustaining load level on flexural behavior of RC beams retrofitted with CFRP sheets [J]. China Civil Engineering Journal,2006,39(1):13-20.(in Chinese)
[11] 黄慧明,易伟建.粘贴碳纤维片材加固钢筋混凝土梁正截面承载力试验研究[J].湖南大学学报:自然科学版,2001,28(3):121-126.
  Huang Huiming,Yi Weijian.Experiment study about flexural behavior of RC beams strengthened with CFRP laminates [J].Journal of Hunan Univerisity:Natural Science,2001,28(3):121-126.(in Chinese)
[12] Manders P W,Baner M G.The strength of hybrid glass/carbon fiber composites,part 1:failure strain enhancement and failure mode [J].Journal of Materials Science,1981,16(8):2233-2245.
[13] 赵彤,谢剑,戴自强.碳纤维布加固钢筋混凝土梁的受弯承载力试验研究[J].建筑结构,2000,30(7):11-15.
  Zhao Tong,Xie Jian,Dai Ziqiang.Experimental study on flexural strength of RC beams strengthened with continuous carbon fiber sheet [J].Building Structure,2000,30(7):11-15.(in Chinese)

相似文献/References:

[1]朱虹,张赟,周臻,等.L形FRP粘贴法加固混凝土框架梁负弯矩区试验研究[J].东南大学学报(自然科学版),2013,43(5):905.[doi:10.3969/j.issn.1001-0505.2013.05.001]
 Zhu Hong,Zhang Yun,Zhou Zhen,et al.Experimental study on strengthening of negative moment region of RC frame beams by L-shaped FRP bonding method[J].Journal of Southeast University (Natural Science Edition),2013,43(3):905.[doi:10.3969/j.issn.1001-0505.2013.05.001]
[2]陈春超,邱洪兴.透榫节点的受弯性能[J].东南大学学报(自然科学版),2016,46(2):326.[doi:10.3969/j.issn.1001-0505.2016.02.016]
 Chen Chunchao,Qiu Hongxing.Flexural behavior of penetrated mortise-tenon joints[J].Journal of Southeast University (Natural Science Edition),2016,46(3):326.[doi:10.3969/j.issn.1001-0505.2016.02.016]
[3]陈春超,邱洪兴,包轶楠,等.不对称榫卯节点正反向受弯性能试验研究[J].东南大学学报(自然科学版),2014,44(6):1224.[doi:10.3969/j.issn.1001-0505.2014.06.023]
 Chen Chunchao,Qiu Hongxing,Bao Yinan,et al.Experimental study on positive and reverse flexural behavior of asymmetric mortise-tenon joints[J].Journal of Southeast University (Natural Science Edition),2014,44(3):1224.[doi:10.3969/j.issn.1001-0505.2014.06.023]
[4]崔文潇,刘琛,陈忠范,等.竖向拼缝对装配式空心井字楼盖受弯性能的影响[J].东南大学学报(自然科学版),2018,48(1):106.[doi:10.3969/j.issn.1001-0505.2018.01.016]
 Cui Wenxiao,Liu Chen,Chen Zhongfan,et al.Influences of vertical joints on flexural performance of fabricated hollow cross-grid floor slabs[J].Journal of Southeast University (Natural Science Edition),2018,48(3):106.[doi:10.3969/j.issn.1001-0505.2018.01.016]

备注/Memo

备注/Memo:
作者简介: 张普(1982—),男,博士生; 吴刚(联系人),男,博士,教授,博士生导师, g.wu@seu.edu.cn.
基金项目: “十一五”国家科技支撑计划资助项目(2006BAJ03B07)、国家自然科学基金资助项目(50608015)、江苏建设系统(建筑业)科研计划资助项目(JG2007-16).
引文格式: 张普,朱虹,孟少平,等.混杂FRP-混凝土T形组合梁受弯性能试验研究[J].东南大学学报:自然科学版,2010,40(3):548-553. [doi:10.3969/j.issn.1001-0505.2010.03.022]