[1]张红,陈熙源,邹升.原子自旋磁强计磁屏蔽筒参数优化设计[J].东南大学学报(自然科学版),2014,44(6):1177-1180.[doi:10.3969/j.issn.1001-0505.2014.06.015]
 Zhang Hong,Chen Xiyuan,Zou Sheng.Parameter optimization design of magnetic shielding cylinders for atomic spin magnetometer[J].Journal of Southeast University (Natural Science Edition),2014,44(6):1177-1180.[doi:10.3969/j.issn.1001-0505.2014.06.015]
点击复制

原子自旋磁强计磁屏蔽筒参数优化设计()
分享到:

《东南大学学报(自然科学版)》[ISSN:1001-0505/CN:32-1178/N]

卷:
44
期数:
2014年第6期
页码:
1177-1180
栏目:
数学、物理学、力学
出版日期:
2014-11-20

文章信息/Info

Title:
Parameter optimization design of magnetic shielding cylinders for atomic spin magnetometer
作者:
张红陈熙源邹升
东南大学微惯性仪表与先进导航技术教育部重点实验室, 南京 210096
Author(s):
Zhang Hong Chen Xiyuan Zou Sheng
Key Laboratory of Micro-Inertial Instrument and Advanced Navigation Technology of Ministry of Education, Southeast University, Nanjing 210096, China
关键词:
原子自旋磁强计 磁屏蔽 参数优化 Ansoft 屏蔽效能
Keywords:
atomic spin magnetometer magnetic shielding parameter optimization Ansoft shielding effectiveness
分类号:
O441.2
DOI:
10.3969/j.issn.1001-0505.2014.06.015
摘要:
为解决磁屏蔽筒制约原子自旋磁强计灵敏度的问题,通过改进多层磁屏蔽筒轴向系数公式获得磁屏蔽筒参数优化模型,并在仅改变一项参数而其他参数固定的条件下,依据优化模型,利用Matlab软件对各参数对轴向屏蔽系数的影响程度进行仿真.结果表明:随着最内层筒半径、筒长及径向层间距的增大,轴向屏蔽系数迅速减小;轴向间隙越大,则屏蔽系数越大.根据仿真结果及实际应用需要优化设计磁屏蔽筒参数,并利用Ansoft软件对优化筒和非优化筒的屏蔽效果进行仿真.结果表明,在外界磁场相同的情况下,未优化和经优化设计的磁屏蔽筒屏蔽能效分别约为152.1和158.6 dB.因此,通过参数优化模型可获得体积小、质量轻、成本低、屏蔽性能大的磁屏蔽筒.
Abstract:
To solve the problem that the sensitivity of atomic spin magnetometer is restricted by magnetic shielding cylinders, the parameter optimization models of magnetic shielding cylinders are designed by improving the axial coefficient formula of multilayered magnetic shielding cylinders. With the change of one parameter while the others keep fixed, according to the optimization models, the influences of parameters on the axial shielding factor are simulated by using Matlab software. The simulation results show that with the increase of the innermost radius, innermost length and radial gap, the axial shielding factor decreases quickly. The larger the axial clearance, the greater the shielding factor. According to the simulation results and the practical application needs, the parameters of magnetic shielding cylinders are optimized. The comparison of the shielding effects between the non-optimized and optimized magnetic shielding cylinders is carried out by Ansoft software. The results show that under the same external magnetic field, the shielding effectiveness of the non-optimized and optimized magnetic shielding cylinders are about 152.1 and 158.6 dB, respectively. Therefore, by the parameter optimization models, the magnetic shielding cylinders with small size, light weight, low cost, and great performance can be obtained.

参考文献/References:

[1] Kornack T W. A test of CPT and Lorentz symmetry using a K-3He co-magnetometer[D]. Princeton, New Jersey, USA: Princeton University, 2005.
[2] Seltzer S J. Developments in alkali-metal atomic magnetometry[D]. Princeton, New Jersey, USA: Princeton University, 2008.
[3] Wickenbrock A, Tricot F, Renzoni F. Magnetic induction measurements using an all-optical 87Rb atomic magnetometer[J]. Applied Physics Letters, 2013, 103(24): 243503-1-243503-4.
[4] Bickel S H. Small signal compensation of magnetic fields resulting from aircraft maneuvers[J]. IEEE Transactions on Aerospace and Electronic Systems, 1979, AES-15(4): 518-525.
[5] Wyllie I R. The development of a multichannel atomic magnetometer array for fetal magnetocardiography[D]. Madison, WI, USA: University of Wisconsin, 2012.
[6] Dang H B, Maloof A C, Romalis M V. Ultrahigh sensitivity magnetic field and magnetization measurements with an atomic magnetometer[J]. Applied Physics Letters, 2010, 97(15): 151110-1-151110-3.
[7] 周建军,林春生,胡叶青,等. 用于磁探测的铁磁屏蔽体的形状与尺寸设计[J]. 磁性材料及器件, 2012, 43(4): 49-53.
  Zhou Jianjun, Lin Chunsheng, Hu Yeqing, et al. Shape and size design of ferromagnetic shield for magnetic detection[J]. Journal of Magnetic Materials and Devices, 2012, 43(4): 49-53.(in Chinese)
[8] 李金涛,房建成. 高精度光纤IMU的磁屏蔽方法及实验研究[J]. 航空学报, 2011,32(11): 2106-2116.
  Li Jintao, Fang Jiancheng. Magnetic shielding method and experiment study of inertial measurement unit based on high precision fiber-optic gyroscope[J]. Acta Aeronautica et Astronautica Sinica, 2011,32(11): 2106-2116.(in Chinese)
[9] 孙威,刘卫,孙佃庆,等. 核磁共振测井仪探头内部磁屏蔽问题的解决方法[J]. 现代科学仪器, 2008(4): 14-15.
  Sun Wei, Liu Wei, Sun Dianqing, et al. Solution of the probe internal magnetic shield in a NMR logging system[J]. Modern Scientific Instruments, 2008(4): 14-15.(in Chinese)
[10] 焦重庆,牛帅. 开孔矩形腔体的近场电磁屏蔽效能研究[J]. 物理学报, 2013,62(11): 114102-1-114102-9.
  Jiao Chongqing, Niu Shuai. Shielding effectiveness of an apertured rectangular cavity against the near-field electromagnetic waves[J], Acta Phys Sin, 2013,62(11): 114102-1-114102-9(in Chinese)
[11] 王晓蔚,任士焱,杨华云,等. 磁屏蔽效能的有限元分析[J]. 计量学报,2006, 27(4): 376-379.
  Wang Xiaowei, Ren Shiyan, Yang Huayun, et al. FEM analysis of magnetic shielding effectiveness[J]. Acta Metrologica Sinica, 2006, 27(4): 376-379.(in Chinese)
[12] Ghosh R K. Spin exchange optical pumping of neon and its applications[D]. Princeton, New Jersey, USA: Princeton University, 2009.
[13] Sumner T J, Pendlebury J M, Smith K F. Convectional magnetic shielding[J]. Journal of Physics D: Applied Physics, 1987, 20(9): 1095-1101.
[14] Kornack T W, Romalis M V. Dynamics of two overlapping spin ensembles interacting by spin exchange[J]. Physical Review Letters, 2002, 89(25): 253002-1-253002-4.
[15] 卢凤喜. 磁屏蔽材料[J]. 钢铁研究,2001(3): 14.

备注/Memo

备注/Memo:
收稿日期: 2014-04-07.
作者简介: 张红(1986—),女,博士生;陈熙源(联系人),男,博士,教授,博士生导师,chxiyuan@seu.edu.cn.
基金项目: 国家自然科学基金资助项目(51375087)、中央高校基本科研业务费专项资金资助项目(CXLX13_083)、高等学校博士学科点专项科研基金资助项目(20110092110039).
引用本文: 张红,陈熙源,邹升.原子自旋磁强计磁屏蔽筒参数优化设计[J].东南大学学报:自然科学版,2014,44(6):1177-1180. [doi:10.3969/j.issn.1001-0505.2014.06.015]
更新日期/Last Update: 2014-11-20