Title:
Calculation method for OVH descriptor based on morphology and its application in radiation treatment plan retrieval
作者:
周正东张雯雯余子丽陈元华
南京航空航天大学核科学与工程系, 南京 210016
Author(s):
Zhou Zhengdong Zhang Wenwen Yu Zili Chen Yuanhua
Department of Nuclear Science and Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing 210016, China
关键词:
IMRT计划检索 重叠体积直方图 形态学 膨胀 腐蚀
Keywords:
intensity modulated radiation therapy(IMRT)plan retrieval overlap volume histogram(OVH) morphology dilation erosion
分类号:
TP391;R318
DOI:
10.3969/j.issn.1001-0505.2015.05.008
摘要:
提出了一种基于形态学的OVH描述子计算方法,并评估了其在IMRT计划检索方面的性能.首先,将靶区与危及器官之间的最小距离和最大距离分别作为靶区收缩/扩张的起始点和终止点,并根据此最小距离和最大距离确定收缩/扩张的合适步长;然后,利用形态学膨胀/腐蚀原理对病例的计算机断层扫描数据进行处理,完成OVH描述子的有效计算;最后,以OVH曲线之间的面积为度量尺度,利用28个鼻咽癌病例评价了基于OVH描述子的IMRT计划检索的性能.实验结果表明,该方法能够有效准确地计算出OVH描述子,利用OVH描述子能够有效检索出形状相似度较高的病例.
Abstract:
A calculation method for the overlap volume histogram(OVH)descriptor based on morphology is proposed,and its performance in intensity modulated radiation therapy(IMRT)plan retrieval is evaluated. First, the minimum distance and the maximum distance between the target and organs at risk are taken as the start point and the end point of contraction/expansion operation, respectively, and the suitable step of contraction/expansion operation is determined according to the minimum distance and the maximum distance. Then, the principle of morphology dilation/erosion is employed to process the computer tomography(CT)data of cases and compute the OVH descriptor effectively. Finally, 28 nasopharyngeal carcinoma(NPC)cases are employed to evaluate the retrieval performance of IMRT plan with the area between OVH curves being taken as the similarity measurement. The experimental results show that the proposed method can calculate the OVH descriptor effectively, and the OVH descriptor can be effectively used to retrieval the IMRT cases with high similarity.

参考文献/References:

[1] Kristensen C A, Kjær-Kristoffersen F, Sapru W, et al. Nasopharyngeal carcinoma. Treatment planning with IMRT and 3D conformal radiotherapy[J]. Acta Oncologica, 2007, 46(2): 214-220.
[2] Djajaputra D, Wu Q, Wu Y, et al. Algorithm and performance of a clinical IMRT beam-angle optimization system[J]. Physics in Medicine and Biology, 2003, 48(19): 3191-3212.
[3] Pugachev A, Li J G, Boyer A L, et al. Role of beam orientation optimization in intensity-modulated radiation therapy[J]. International Journal of Radiation Oncology Biology Physics, 2001, 50(2): 551-560.
[4] 周正东.一种基于检索的放射治疗计划系统及检索方法:中国,ZL201110129576.4[P].2011-09-14.
[5] Kazhdan M, Simari P, McNutt T, et al. A shape relationship descriptor for radiation therapy planning[J]. Lecture Notes in Computer Science, 2009, 5762: 100-108.
[6] Wu B, Ricchetti F, Sanguineti G, et al. Patient geometry-driven information retrieval for IMRT treatment plan quality control[J]. Medical Physics, 2009, 36(12): 5497-5505.
[7] Wu B, Ricchetti F, Sanguineti G, et al. Data-driven approach to generating achievable dose-volume histogram objectives in intensity-modulated radiotherapy planning[J]. International Journal of Radiation Oncology Biology Physics, 2011, 79(4): 1241-1247.
[8] Petit S,Wu B, Kazhdan M, Simari P, et al. Increased organ sparing using shape-based treatment plan optimization for intensity modulated radiation therapy of pancreatic adenocarcinoma[J]. Radiotherapy and Oncology, 2011, 102(1): 38-44.
[9] Zhou Zhengdong, Chen Yuanhua, Yu Zili, et al. A study of quality control method for IMRT planning based on prior knowledge and novel measures derived from both OVHs and DVHs[J]. Bio-Medical Materials and Engineering, 2014, 24(6): 3479-3485.
[10] 王东东,周正东,宋威,等.重叠体积直方图描述子的计算方法和其在鼻咽癌IMRT计划检索中的应用[J].中国生物医学工程学报,2014,33(3):373-378.
  Wang Dongdong, Zhou Zhengdong, Song Wei, et al. The calculation method of overlap volume histogram and its usage in nasopharyngeal carcinoma IMRT plans retrieval[J]. Chinese Journal of Biomedical Engineering, 2014, 33(3): 373-378.(in Chinese)
[11] 蒲石,龙文光.基于膨胀和腐蚀的迭代优化算法[J].四川师范大学学报:自然科学版,2014,37(3):408-412.
  Pu Shi, Long Wenguang. An optimization algorithm for delation and eroison based on iterative calculation[J]. Journal of Sichuan Normal University: Natural Science, 2014, 37(3): 408-412.(in Chinese)
[12] 甘明刚,陈杰,刘劲,等.一种基于三帧差分和边缘信息的运动目标检测方法[J].电子与信息学报,2010,32(4):894-897.
  Gan Minggang, Chen Jie, Liu Jin, et al. Moving object detection algorithm based on three-frame-differencing and edge information[J]. Journal of Electronics & Information Technology, 2010, 32(4): 894-897.(in Chinese)

备注/Memo

备注/Memo:
收稿日期: 2015-04-22.
作者简介: 周正东(1969—),男,博士,副教授, zzd_msc@nuaa.edu.cn.
基金项目: 中央高校基本科研业务费专项资金资助项目(NP2015101)、江苏省高校优势学科建设工程资助项目.
引用本文: 周正东,张雯雯,余子丽,等.基于形态学的OVH描述子计算方法及其在放疗计划检索中的应用[J].东南大学学报:自然科学版,2015,45(5):856-860. [doi:10.3969/j.issn.1001-0505.2015.05.008]
更新日期/Last Update: 2015-09-20