参考文献/References:
[1] 刘志坦, 惠润堂, 杨爱勇, 等. 燃煤电厂湿烟羽成因及对策研究[J]. 环境与发展, 2017, 29(10): 43-46. DOI:10.16647/j.cnki.cn15-1369/X.2017.10.023.
Liu Z T, Hui R T, Yang A Y, et al. Rearch on causes and countermeasures of the wet plume in coal-fired power plant[J]. Environment and Development, 2017, 29(10): 43-46. DOI:10.16647/j.cnki.cn15-1369/X.2017.10.023. (in Chinese)
[2] 何平, 李树生, 朱维群, 等. 湿法脱硫如何导致大面积雾霾[J]. 科学与管理, 2017, 37(6): 7-11.
He P, Li S S, Zhu W Q, et al. How wet desulfurization cause large area smog[J]. Science and Management, 2017, 37(6): 7-11.(in Chinese)
[3] Wei M L, Yuan W X, Song Z J, et al. Simulation of a heat pump system for total heat recovery from flue gas[J]. Applied Thermal Engineering, 2015, 86: 326-332. DOI:10.1016/j.applthermaleng.2015.04.061.
[4]Wang Z Y, Zhang X Y, Han J F, et al. Waste heat and water recovery from natural gas boilers: Parametric analysis and optimization of a flue-gas-driven open absorption system[J]. Energy Conversion and Management, 2017, 154: 526-537. DOI:10.1016/j.enconman.2017.11.042.
[5] Folkedahl B C, Weber G F, Collings M E. Water extraction from coal-fired power plant flue gas[R]. Grand Forks,ND,USA: University of North Dakota, 2006.
[6] 魏璠, 肖云汉, 张士杰, 等. 喷淋吸收过程模型及实验研究[J]. 工程热物理学报, 2008, 29(10): 1621-1624. DOI:10.3321/j.issn:0253-231X.2008.10.001.
Wei F, Xiao Y H, Zhang S J, et al. The model and experiment of heat and mass transfer in spraying absorption[J]. Journal of Engineering Thermophysics, 2008, 29(10): 1621-1624. DOI:10.3321/j.issn:0253-231X.2008.10.001. (in Chinese)
[7] 路源, 徐震, 肖云汉. 开式吸收式热泵降膜吸收器实验研究[J]. 太阳能学报, 2011, 32(8): 1158-1162.
Lu Y, Xu Z, Xiao Y H. Experimental study of the falling film absorber in the open cycle absorption heat pump[J]. Acta Energiae Solaris Sinica, 2011, 32(8): 1158-1162.(in Chinese)
[8] 吕扬. 低温湿烟气溶液除湿技术试验研究[D]. 济南: 山东大学, 2017.
Lü Y. Experimental study on liquid desiccant-based dehydration under low-temperature wet flue gas[D]. Jinan: Shandong University, 2017.(in Chinese)
[9] 刘晓华. 溶液调湿式空气处理过程中热湿耦合传递特性分析[D]. 北京: 清华大学建筑学院, 2007.
Liu X H. Combined heat and mass transfer characteristic in air handling process using liquid desiccant[D]. Beijing: Tsinghua University, 2007.(in Chinese)
[10] Liu X H, Jiang Y, Qu K Y. Heat and mass transfer model of cross flow liquid desiccant air dehumidifier/regenerator[J]. Energy Conversion and Management, 2007, 48(2): 546-554. DOI:10.1016/j.enconman.2006.06.002.
[11] Zhang L, Liu X H, Wei H Y, et al. Experimental study and analysis of heat and mass transfer ability of counter-flow packing tower and liquid desiccant dehumidification system[J]. Energy and Buildings, 2018, 158: 150-161. DOI:10.1016/j.enbuild.2017.10.016.
[12] Conde M R. Properties of aqueous solutions of lithium and calcium chlorides: Formulations for use in air conditioning equipment design[J]. International Journal of Thermal Sciences, 2004, 43(4): 367-382. DOI:10.1016/j.ijthermalsci.2003.09.003.
[13] 连之伟. 热质交换原理与设备 [M]. 3版. 北京: 中国建筑工业出版社, 2011:128-135.
[14] Goshayshi H R, Missenden J F. The investigation of cooling tower packing in various arrangements[J]. Applied Thermal Engineering, 2000, 20(1): 69-80. DOI:10.1016/s1359-4311(99)00011-3.