[1]卢熹,杨瑛.下颌骨-牙种植体有限元建模与瞬态分析[J].东南大学学报(自然科学版),2010,40(4):722-725.[doi:10.3969/j.issn.1001-0505.2010.04.011]
 Lu Xi,Yang Ying.Stress wave efforts of implant-bone under impact loading[J].Journal of Southeast University (Natural Science Edition),2010,40(4):722-725.[doi:10.3969/j.issn.1001-0505.2010.04.011]
点击复制

下颌骨-牙种植体有限元建模与瞬态分析()
分享到:

《东南大学学报(自然科学版)》[ISSN:1001-0505/CN:32-1178/N]

卷:
40
期数:
2010年第4期
页码:
722-725
栏目:
生物医学工程
出版日期:
2010-07-20

文章信息/Info

Title:
Stress wave efforts of implant-bone under impact loading
作者:
卢熹 杨瑛
东南大学机械工程学院,南京 211189
Author(s):
Lu Xi Yang Ying
School of Mechanical Engineering, Southeast University, Nanjing 211189, China
关键词:
牙种植体 下颌骨 有限元 冲击载荷 应力波
Keywords:
dental implant mandible finite element impact loading stress wave
分类号:
R78
DOI:
10.3969/j.issn.1001-0505.2010.04.011
摘要:
通过逆向工程技术,将二维的下颌骨CT图片转化为三维有限元模型.根据CT图片像素的Hounsfield值将颌骨材料划分为10种材料属性,并建立含种植体的下颌骨有限元计算模型.以冲击载荷模拟牙齿咀嚼时的力作用,计算下颌骨-种植体在此冲击载荷作用下的响应:当应力波首次传到种植体-下颌骨界面时,在种植体上部第1圈螺纹的根部出现局部的应力峰值8.21MPa, 而当种植体-下颌骨的整体应变能达到最高峰时,在种植体的末端附近出现了全局应力峰值11.51MPa.静态和瞬态时的最大应力差超过40%,出现的位置也不同,由此可知,动态分析对种植牙的结构设计很重要.
Abstract:
By reverse engineering, the two-dimensional mandible CT(computed tomography)images were converted into a three-dimensional FE(finite element)model. The FE model’s material properties were taken into considerations according to the Hounsfield Units of original CT image pixels. The simulation of stress wave efforts of dental implant under impact loading were carried out. The Von mises stress reaches a local peak value of 8.21MPa when the stress wave first arrives at the mandible-implant interface. Whereas when the stress wave first bounces back after it reaches the end of the implant, the global peak value of the Von mises stress reaches 11.51MPa; The difference of maximum Von mises stress between static analysis and dynamic analysis is more than 40% and their locations are variable. That means it’s important to verify the dynamic properties of the dental implant as well as static properties.

参考文献/References:

[1] 陈良建,李益民.钛种植体结构和弹性模量对骨界面应力分布的影响[J].中南大学学报,2009,40(1):400-405.
  Chen Liangjian,Li Yimin.Influence of structure and elastic modulus of titanium implanimplant on implant-bone interfacial stress distribution [J].Journal of Central South University,2009,40(1):400-405.(in Chinese)
[2] 杜燚,叶平,吴润发.三维有限元分析过盈配合对种植体骨界面应力分布的影响[J].中国口腔种植学杂志,2008,13(1):22-24.
  Du Yi,Ye Ping,Wu Runfa.3D-finite element method analysis of influence of interference fit on bone-implant surface stress distribution[J].Chinese Journal of Oral Implantology,2008,13(1):22-24.(in Chinese)
[3] Chun H J,Cheong S Y,Han J H,et al.Effects of design parameters of osseointegrated implant on stress distribution in jaw bone[C] //22nd Annual International Conference of the IEEE Engineering in Medicine and Biology Society.Chicago,USA,2000,1:725-729.
[4] Pierrisnard L,Hure G,Barquins M,et al.Two dental implants designed for immediate loading:a finite element analysis[J].Int J Oral Maxillofac Implants,2002,17(3):353-362.
[5] Prakash Vijay,D’Souza Mariette,Adhikari Raviraj.A comparison of stress distribution and flexion among various designs of bar attachments for implant overdentures:a three dimensional finite element analysis[J].Indian J Dent Res,2009,20(1):31-36.
[6] Greco Gustavo Diniz,Jansen Wellington Correa,Landre Junior Janis,et al.Stress analysis on the free-end distal extension of an implant-supported mandibular complete denture[J].Braz Oral Res,2009,23(2):182-189.
[7] de Cos Juez F J,Lasheras F Sanchez,Niet Garcia P J.Non-linear numerical analysis of a double-threaded titanium alloy dental implant by FEM [J].Applied Mathematics and Computation,2008,20(6):952-967.
[8] Yang Jie,Xiang Hongjun.A three-dimensional finite element study on the biomechanical behavior of an FGBM dental implant in surrounding bone [J].Journal of Biomechanics,2007,40(11):2377-2385.
[9] Javier Gil F,Planell Josep A,Alejandro Padr.The effect of shot blasting and heat treatment on the fatigue behavior of titanium for dental implant applications[J].Dental Materials,2007,23(4):486-491.
[10] Luigi Baggi,Ilaria Cappelloni,Franco Maceri.Stress-based performance evaluation of osseointegrated dental implants by finite-element simulation[J].Simulation Modeling Practice and Theory,2008,16(8):971-987.
[11] Suedam V,Capello Souza E A,Moura M S,et al.Effect of abutment’s height and framework alloy on the load distribution of mandibular cantilevered implant-supported prosthesis[J].Clinical Implants Research,2009,20(2):196-200.
[12] Wierszycki Marcin,Kakol Witold,Lodygowski Tomasz.Fatigue algorithm for dental implant[J].Foundations of Civilil an Environmental Engineering,2006(7):364-380.
[13] 钱茹,汤春波,卢熹.种植义齿部件有限元建模与试验研究[J].南京医科大学学报,2008,28(11):1441-1444.
  Qian Ru,Tang Chunbo,Lu Xi.Study on finite element modeling and mechanical test of implant prosthese components[J].Acta University Medicinalis Nanjing,2008,28(11):1441-1444.(in Chinese)
[14] Rho J Y,Hobatho M C,Ashman R B.Relations of mechanical properties to density and CT numbers in human bone[J].Medical Engineering and Physics,1995,17(5):347-355.
[15] Taylor W R,Roland E,Ploeg H,et al.Determination of orthotropic bone elastic constants using FEA and modal analysis[J].Journal of Biomechanics,2002,35(6):767-773.
[16] Pereza M A,Moreoa P,Garc Aznara J M.Computational simulation of dental implant osseointegration through resonance frequency analysis[J].Journal of Biomechanics,2008,41(2):316-325.

备注/Memo

备注/Memo:
作者简介: 卢熹(1968—),男,博士,副教授,seu-luxi@yahoo.com.cn.
引文格式: 卢熹,杨瑛.下颌骨-牙种植体有限元建模与瞬态分析[J].东南大学学报:自然科学版,2010,40(4):722-725. [doi:10.3969/j.issn.1001-0505.2010.04.011]
更新日期/Last Update: 2010-07-20