[1]刘鑫,刘伟庆,王曙光,等.加固加层隔震结构阻尼比特性的振动台试验[J].东南大学学报(自然科学版),2012,42(6):1151-1156.[doi:10.3969/j.issn.1001-0505.2012.06.024]
 Liu Xin,Liu Weiqing,Wan Shuguang,et al.Shaking table test of damping ratio of strengthening-adding-story isolation structures[J].Journal of Southeast University (Natural Science Edition),2012,42(6):1151-1156.[doi:10.3969/j.issn.1001-0505.2012.06.024]
点击复制

加固加层隔震结构阻尼比特性的振动台试验()
分享到:

《东南大学学报(自然科学版)》[ISSN:1001-0505/CN:32-1178/N]

卷:
42
期数:
2012年第6期
页码:
1151-1156
栏目:
土木工程
出版日期:
2012-11-20

文章信息/Info

Title:
Shaking table test of damping ratio of strengthening-adding-story isolation structures
作者:
刘鑫 刘伟庆 王曙光 杜东升
南京工业大学土木工程学院,南京 211816
Author(s):
Liu Xin Liu Weiqing Wan Shuguang Du Dongsheng
College of Civil Engineering, Nanjing University of Technology, Nanjing 211816, China
关键词:
加固加层隔震结构 阻尼比 振动台试验 刚度比
Keywords:
strengthening-adding-story isolation structures damping ratio shaking table test stiffness ratio
分类号:
TU399
DOI:
10.3969/j.issn.1001-0505.2012.06.024
摘要:
利用振动台试验研究了由砌体、混凝土加固墙板、顶部隔震钢框架组成的复杂结构的阻尼比特性.首先,建立了5层加固、加层不隔震以及加层隔震3种试验模型; 然后,利用特征系统实现算法(ERA)对这3种模型的扫频数据进行模态拟合,识别试验模型在不同地震波输入量级下的结构阻尼比,并分析其随地震波输入量级的变化规律.试验结果表明,对于非隔震结构,随着地震波输入量级的增加,结构发生刚度退化,结构阻尼比增加; 对于加层隔震结构,随着地震波输入量级的增加,隔震层下部的砌体结构损伤不断累积,使得上部结构与下部结构的刚度比增加,整体结构的一阶阻尼比减小,二阶阻尼比增加.试验数据分析所得的3种试验模型的阻尼比变化规律与现有理论分析结果一致.该试验结果为由不同材料组成的不同结构体系在地震作用下的阻尼比取值提供了相关依据及参考.
Abstract:
The damping ratio of a complex structure composed of masonry, concrete reinforced wall and isolation steel framework was studied by shaking table tests. First, three test models, five-story strengthening structure, strengthening-adding-story structure and strengthening-adding-story isolation structure, were set up. Then, the sweeping date of these three models were fitted by the eigensystem realization algorithm(ERA). The damping ratios of these test models were identified under the different levels of the ground motions and the variation of damping ratios with the increase of the ground motions were studied. The experimental results show that, with the increase of ground motions, the stiffness of the non-isolated structure decreases while the damping ratio of the structure increases. For the mid-story isolation structure, the damage of masonry accumulates gradually with the increase of ground motions, inducing the increase of the stiffness ratio between superstructure and substructure, the decrease of the first-order damping ratio and the increase of the second-order damping ratio of the structure. The development trends of the damping ratio of these three test models are accorded with the theoretical analysis. The experimental results provide basis and reference for choosing proper damping ratios for different structure systems with different materials.

参考文献/References:

[1] 段绍伟,向湘林,沈蒲生.复杂阻尼结构阻尼模型研究[J].振动与冲击,2011,30(2):73-76.
  Duan Shaowei,Xiang Xianglin,Shen Pusheng.Damping model of a complex structure[J].Journal of Vibration and Shock,2011,30(2):73-76.(in Chinese)
[2] 中华人民共和国住房和城乡建设部.GB50011—2010 建筑抗震设计规范[S].北京:中国建筑工业出版社,2010.
[3] Ducan P E,Taylor E R.A note on the dynamic analysis of non-proportional damped systems [J].Earthquake Engineering and Structural Dynamics, 1979,7(1):99-105.
[4] Novak M,Hifnaway L E.Effect of soil-structure-interaction on damping of structure [J].Earthquake Engineering and Structural Dynamics, 1983,11(5):595-621.
[5] 刘庆林,傅学怡,孙占琦.基于复阻尼假定的不同材料阻尼特性混合结构抗震分析复模态叠加法[J].建筑结构学报,2011,32(9):27-33.
  Liu Qinglin,Fu Xueyi,Sun Zhanqi.A complex mode superposition method for seismic analysis of structures of multiple material damping characteristics based on complex damping assumption [J].Journal of Building Structures, 2011,32(9):27-33.(in Chinese)
[6] Berman A,Nagy E Y.Improvement of a large analytical model using test data [J].The American Institute of Aeronautics and Astronautics Journal, 1983,21(8):1168-1173.
[7] 俞瑞芳,周锡元.非比例阻尼弹性结构地震反应强迫解耦方法的背景和数值检验[J].工业建筑,2005,35(2):52-56.
  Yu Ruifang,Zhou Xiyuan.Theoretical and numerical research on forced uncoupling method for seismic response of non-classically damped linear system[J].Industrial Construction, 2005,35(2):52-56.(in Chinese)
[8] 淡丹辉,孙利民.结构动力有限元的模态阻尼比单元阻尼建模法[J].振动、测试与诊断,2008,28(2):100-103.
  Dan Danhui,Sun Limin.Damping modeling and its evaluation based on dynamical analysis of engineering structure by finite element method [J].Journal of Vibration,Measurement & Diagnosis, 2008,28(2):100-103.(in Chinese)
[9] Clough R W,Penzien J.Dynamics of structures [M].2nd ed.Berkeley,California,USA:Computer and Structures,Inc.,1995:237-242.
[10] Chung Woo-Jung,Yun Chung-Bang.Shaking table and pseudo-dynamic tests for the evaluation of the seismic performance of base-isolated structures [J].Engineering Structures, 1999,21(4):365-379.
[11] Cheng Chin-Tung.Shaking table tests of a self-centering designed bridge substructure [J].Engineering Structures, 2008,30(12):3426-3433.
[12] 閤东东,陈曦,苗启松,等.砌体结构房屋加固足尺实验模型数值模拟[J].土木工程与管理学报,2011,28(3):344-348.
  Ge Dongdong,Chen Xi,Miao Qisong,et al.Numerical research on a full-scale masonry building retrofitted by external precast structure[J].Journal of Civil Engineering and Management, 2011,28(3):344-348.(in Chinese)
[13] 顾培英,邓昌,吴福生.结构模态分析及其损伤诊断[M].南京:东南大学出版社,2008:79-82.
[14] 杨佑发,王立福,王功.在非比例阻尼情况下层间隔震底层框架砖房的组合阻尼比[J].工业建筑,2003,33(12):47-49.
  Yang Youfa,Wang Lifu,Wang Gong.On calculation of the non-proportional damping effect for the interlayer isolation masonry building with frame structure in the first storey [J].Industrial Construction, 2003,33(12):47-49.(in Chinese)

相似文献/References:

[1]茅建校,王浩,程怀宇,等.基于小波变换的台风激励下千米级斜拉桥模态参数识别[J].东南大学学报(自然科学版),2015,45(1):159.[doi:10.3969/j.issn.1001-0505.2015.01.028]
 Mao Jianxiao,Wang Hao,Cheng Huaiyu,et al.Modal parameter identification of kilometer cable-stayed bridge under typhoon excitation based on wavelet transform[J].Journal of Southeast University (Natural Science Edition),2015,45(6):159.[doi:10.3969/j.issn.1001-0505.2015.01.028]
[2]石文博,缪林昌,王佳奇,等.循环荷载作用下不同配比EPS轻质混凝土阻尼比变化规律[J].东南大学学报(自然科学版),2016,46(1):179.[doi:10.3969/j.issn.1001-0505.2016.01.029]
 Shi Wenbo,Miao Linchang,Wang Jiaqi,et al.Damping behavior of lightweight expanded polystyrene concrete under dynamic cyclic loading[J].Journal of Southeast University (Natural Science Edition),2016,46(6):179.[doi:10.3969/j.issn.1001-0505.2016.01.029]

备注/Memo

备注/Memo:
作者简介: 刘鑫(1988—),男,博士生; 刘伟庆(联系人),男,博士,教授,博士生导师,wqliu@njut.edu.cn.