[1]马良栋,张志远,宋嘉林,等.城市原生污水基础物性参数测试[J].东南大学学报(自然科学版),2018,48(6):1177-1182.[doi:10.3969/j.issn.1001-0505.2018.06.028]
 Ma Liangdong,Zhang Zhiyuan,Song Jialin,et al.Test of basic physical parameters of urban untreated sewage[J].Journal of Southeast University (Natural Science Edition),2018,48(6):1177-1182.[doi:10.3969/j.issn.1001-0505.2018.06.028]
点击复制

城市原生污水基础物性参数测试()
分享到:

《东南大学学报(自然科学版)》[ISSN:1001-0505/CN:32-1178/N]

卷:
48
期数:
2018年第6期
页码:
1177-1182
栏目:
能源与动力工程
出版日期:
2018-11-20

文章信息/Info

Title:
Test of basic physical parameters of urban untreated sewage
作者:
马良栋张志远宋嘉林张吉礼
大连理工大学建设工程学部, 大连 116024
Author(s):
Ma Liangdong Zhang Zhiyuan Song Jialin Zhang Jili
Faculty of Infrastructure Engineering, Dalian University of Technology, Dalian 116024, China
关键词:
污水源热泵 城市原生污水 物性参数 测试
Keywords:
sewage source heat pump urban untreated sewage physical parameters test
分类号:
TK31
DOI:
10.3969/j.issn.1001-0505.2018.06.028
摘要:
为获得城市原生污水源热泵取水换热工艺系统设计所需的污水物性参数,针对城市多个污水排水泵站的原生污水,实验测试了不同污杂物质量浓度下原生污水密度、黏性系数、导热系数和定压比热,并研究了污水温度对污水物性参数的影响.结果表明:当污水温度从5 ℃到30 ℃变化时,污水密度随温度先增大后减少,其最大值出现在10 ℃附近;在污杂物质量浓度为1.5 g/kg时,污水黏度减小45%,污水导热系数增大7.6%.当污水污杂物质量浓度从0.77 g/kg增大到1.5 g/kg时,污水密度增大1%,黏度增大3.5%,导热系数减少2.1%,定压比热减小6.3%;在污杂物浓度为1.50 g/kg时,在5~30 ℃测试温度范围内,污水黏度均为清水的1.1倍左右.
Abstract:
To obtain the physical parameters of sewage needed for the design of intaking water and heat transfer process system of sewage source heat pump, according to the urban untreated sewage at various sewage pump stations in cities, the basic physical parameters on different suspension mass concentrations, including density, viscosity coefficient, thermal conductivity, and specific heat of constant pressure, were experimentally tested. And the effects of the sewage temperature on physical parameters of the sewage were studied. The results show that the sewage density increases first with the increase of temperature and then decreases when the sewage temperature increases from 5 ℃ to 30 ℃, and the maximum value of the density appears as the sewage temperature is 10 ℃.The viscosity of sewage is decreased by 45% and the thermal conductivity of sewage is increased by 7.6% for the suspended solids mass concentration of 1.5 g/kg. When the mass concentrations of the suspended solids in sewage increase from 0.77 g/kg to 1.5 g/kg, the density of the sewage increase by about 1%, the viscosity of the sewage increase by about 3.5%, the thermal conductivity is decreased by 2.1% and the specific heat of constant pressure is decreased by 6.3%. For the suspended solids mass concentration of 1.50 g/kg, the viscosity of the sewage is about 1.1 times that of clear water within the test temperature range at 5 to 30 ℃.

参考文献/References:

[1] 吴荣华, 刘志斌, 黄磊, 等.污水及地表水地源热泵系统规范化设计研究[J].暖通空调, 2006, 36(12): 63-69. DOI:10.3969/j.issn.1002-8501.2006.12.017.
Wu Ronghua, Liu Zhibin, Huang Lei, et al. Research on standardization design of urban sewage and surface water source heat pump system[J]. Heating Ventilating & Air Conditioning, 2006, 36(12): 63-69. DOI:10.3969/j.issn.1002-8501.2006.12.017. (in Chinese)
[2] 张吉礼, 钱剑峰, 孔祥兵, 等. 铜管换热器内颗粒状污垢生长特性试验分析[J]. 土木建筑与环境工程, 2010, 32(5): 60-64. DOI:10.3969/j.issn.1674-4764.2010.05.010.
Zhang Jili, Qian Jianfeng, Kong Xiangbin, et al. Characteristics of granular fouling growth of sewage in copper pipe heat exchanger[J]. Journal of Chongqing Jianzhu University, 2010, 32(5): 60-64. DOI:10.3969/j.issn.1674-4764.2010.05.010. (in Chinese)
[3] 张承虎, 庄兆意, 吴学慧, 等. 城市污水固态成分相关概念与参数测定[J]. 哈尔滨工业大学学报, 2008, 40(8): 1218-1221. DOI:10.3321/j.issn:0367-6234.2008.08.009.
Zhang Chenghu, Zhuang Zhaoyi, Wu Xuehui, et al. Parameter definition and measuration of solid contaminant in untreated urban sewage[J]. Journal of Harbin Institute of Technology, 2008, 40(8): 1218-1221. DOI:10.3321/j.issn:0367-6234.2008.08.009. (in Chinese)
[4] Wu X H, Wang F, Sun D X, et al. Rheology and flow characteristic of urban untreated sewage for cooling and heating source[J]. Experimental Thermal and Fluid Science, 2011, 35(4): 612-617. DOI:10.1016/j.expthermflusci.2010.11.009.
[5] Liu Z B, Ma L D, Zhang J L. Application of a heat pump system using untreated urban sewage as a heat source[J]. Applied Thermal Engineering, 2014, 62(2): 747-757. DOI:10.1016/j.applthermaleng.2013.08.028.
[6] Song J L, Liu Z B, Ma Z J, et al. Experimental investigation of convective heat transfer from sewage in heat exchange pipes and the construction of a fouling resistance-based mathematical model[J]. Energy and Buildings, 2017, 150: 412-420. DOI:10.1016/j.enbuild.2017.06.025.
[7] 蔡增基, 李炳田. 管道内污水两相流的阻力计算[J]. 管道技术与设备, 2005(3): 12-13,16. DOI:10.3969/j.issn.1004-9614.2005.03.005.
Cai Zengji, Li Bingtian. Calculaton of the drag force of sewage flowing as two-phase fluid in pipe[J]. Pipeline Technique and Equipment, 2005(3): 12-13,16. DOI:10.3969/j.issn.1004-9614.2005.03.005. (in Chinese)
[8] 张承虎, 吴荣华, 刘志斌, 等. 污水源热泵系统双级水泵运行特性研究[J]. 哈尔滨工业大学学报, 2007, 39(10): 1601-1605. DOI:10.3321/j.issn:0367-6234.2007.10.021.
Zhang Chenghu, Wu Ronghua, Liu Zhibin, et al. The operating characteristic research on sewage heat-pump system with tow-stage pumps[J]. Journal of Harbin Institute of Technology, 2007, 39(10): 1601-1605. DOI:10.3321/j.issn:0367-6234.2007.10.021. (in Chinese)
[9] 刘志斌. 双级泵无外挡板污水采集装置防阻塞特性的研究[D]. 哈尔滨:哈尔滨工业大学市政环境工程学院,2006.
[10] 国家技术监督局. GB/T 11901—1989 水质悬浮物的测定重量法[S]. 北京:中国标准出版社,1991.
[11] 徐爱芬. 振动弦黏度/密度计的研究[D]. 杭州:中国计量学院计量测试工程学院,2012.
[12] 孟现阳, 郑平军, 吴江涛. 碳酸二乙酯黏度和密度的实验测量及数据关联[J]. 化工学报, 2008, 59(11): 2695-2700. DOI:10.3321/j.issn:0438-1157.2008.11.001.
Meng Xianyang, Zheng Pingjun, Wu Jiangtao. Measurements of viscosity and density of diethyl carbonate[J]. Journal of Chemical Industry and Engineering(China), 2008, 59(11): 2695-2700. DOI:10.3321/j.issn:0438-1157.2008.11.001. (in Chinese)
[13] 徐智渊, 孟现阳, 吴江涛, 等. 振动弦粘度计研制及MTBE饱和液相粘度实验研究[J]. 工程热物理学报, 2007, 28(2): 189-192. DOI:10.3321/j.issn:0253-231x.2007.02.003.
Xu Zhiyuan, Meng Xianyang, Wu Jiangtao, et al. Development of a vibrating-wire viscometer and measurement of saturated liquid viscosity of methyl tert-butyl ether[J]. Journal of Engineering Thermophysics, 2007, 28(2): 189-192. DOI:10.3321/j.issn:0253-231x.2007.02.003. (in Chinese)
[14] 阎秋会, 刘志刚, 阴建民. 瞬态热线法测量流体导热系数的实验研究[J]. 西安建筑科技大学学报, 1997, 29(3):322-325. DOI:10.15986/j.1006-7930.1997.03.020.
Yan Qiuhui, Liu Zhigang, Yin Jianmin. On the thermal conductivity coefficient of fluid by the transient hot-wire technique[J]. Journal of Xi’an University of Architecture & Technology, 1997, 29(3):322-325. DOI:10.15986/j.1006-7930.1997.03.020. (in Chinese)
[15] 陈文胜,张迎新. 瞬态热线法测量煤层气水合物导热系数的实验研究[J]. 应用能源技术, 2013(4): 37-40. DOI:10.3969/j.issn.1009-3230.2013.04.010.
Chen Wensheng, Zhang Yingxin. Experimental the measurement of thermal conductivity of gas hydrate with transient hot-wire method[J]. Applied of Energy Technology, 2013(4): 37-40. DOI:10.3969/j.issn.1009-3230.2013.04.010. (in Chinese)
[16]方修睦. 建筑环境测试技术[M]. 2版.北京:中国建筑工业出版社,2008:50-51.

备注/Memo

备注/Memo:
收稿日期: 2018-05-22.
作者简介: 马良栋(1976—),男,博士,副教授,liangdma@dlut.edu.cn.
基金项目: 国家自然科学基金资助项目(51676026).
引用本文: 马良栋,张志远,宋嘉林,等.城市原生污水基础物性参数测试[J].东南大学学报(自然科学版),2018,48(6):1177-1182. DOI:10.3969/j.issn.1001-0505.2018.06.028.