[1]聂少锋,周天华,周绪红,等.三肢冷弯薄壁型钢拼合双腔箱形柱受压性能试验研究与数值分析[J].东南大学学报(自然科学版),2019,49(1):25-33.[doi:10.3969/j.issn.1001-0505.2019.01.004]
 Nie Shaofeng,Zhou Tianhua,Zhou Xuhong,et al.Experimental study and numerical analysis on compressive behavior of three-limb built-up cold-formed steel columns with double box section[J].Journal of Southeast University (Natural Science Edition),2019,49(1):25-33.[doi:10.3969/j.issn.1001-0505.2019.01.004]
点击复制

三肢冷弯薄壁型钢拼合双腔箱形柱受压性能试验研究与数值分析()
分享到:

《东南大学学报(自然科学版)》[ISSN:1001-0505/CN:32-1178/N]

卷:
49
期数:
2019年第1期
页码:
25-33
栏目:
土木工程
出版日期:
2019-01-20

文章信息/Info

Title:
Experimental study and numerical analysis on compressive behavior of three-limb built-up cold-formed steel columns with double box section
作者:
聂少锋1周天华1周绪红2左小雨1叶梦娜1
1 长安大学建筑工程学院, 西安 710061; 2 重庆大学土木工程学院, 重庆 400044
Author(s):
Nie Shaofeng1 Zhou Tianhua1 Zhou Xuhong2 Zuo Xiaoyu1 Ye Mengna1
1 School of Civil Engineering, Chang’an University, Xi’an 710061, China
2 School of Civil Engineering, Chongqing University, Chongqing 400044, China
关键词:
冷弯薄壁型钢 三肢拼合双腔箱形柱 参数分析 最大承载力
Keywords:
cold-formed thin-walled steel three-limb built-up column with double boxes section parameter analysis maximum bearing capacity�E䥺Symbol`@@�F
分类号:
TU392.1
DOI:
10.3969/j.issn.1001-0505.2019.01.004
摘要:
对12根三肢冷弯薄壁型钢拼合双腔箱形柱分别进行了轴压、偏压试验和数值模拟分析.通过试验研究,得到了各试件的荷载-位移、荷载-应变曲线以及最大承载力,并分析了屈曲模式和破坏特征.采用有限元软件ABAQUS分析了双腔箱形柱的长细比变化、截面腹板的高厚比变化、荷载偏心方向和偏心距参数对拼合双腔箱形柱受压性能的影响.结果表明,LT-A(长柱)和MT-A(中长柱)组试件的最终破坏模式为整体弯曲屈曲破坏,个别MT-A组试件破坏位置发生在柱端,其余均在柱中.试件的轴压最大承载力均随试件长细比的增大而逐渐减小.试件轴压最大承载力随截面腹板高厚比的减小而增大;偏压试件的最大承载力随着偏心距的增加而降低.
Abstract:
Experimental study and numerical simulation on 12 three-limb built-up columns with double boxes section were carried out to study the compressive behavior under axial and eccentric loading. The load-displacement curves, the load-strain curves and the maximum bearing capacity of the specimens were obtained through the experimental study. The buckling modes and the failure characteristics were analyzed. The finite element software ABAQUS was used to analyze the influence of the slenderness ratio of the columns, the web height to thickness ratio of the section, the eccentricity and the direction of the loading on the compressive behavior of the built-up cold-formed steel columns with double box section. The results show that the final failure mode of the LT-A(long length columns)and MT-A(middle length columns)group specimens are overall flexural buckling damage. Most of the damage locations are in the mid-height of columns, except for the individual specimens of MT-A group. The maximum bearing capacity of the specimens decreases with the increase of the slenderness ratio of the columns. The maximum bearing capacity of the specimens increases with the decrease of the height thickness ratio of the web. The maximum bearing capacity of the specimens under eccentric compression decreases with the increase of the eccentricity.

参考文献/References:

[1] 中华人民共和国住房和城乡建设部. JGJ 227—2011 低层冷弯薄壁型钢结构房屋建筑技术规程[S]. 北京: 中国建筑工业出版社, 2011.
[2] 中华人民共和国住房和城乡建设部. GB 50018—2002 冷弯薄壁型钢结构技术规范[S]. 北京: 中国计划出版社, 2002.
[3] American Iron and Steel Institute. AISI S100—2007 North American specification for the design of cold-formed steel structural members [S]. Washington, DC: American Iron and Steel Institute, 2007.
[4] Reyes W, Guzmán A. Evaluation of the slenderness ratio in built-up cold-formed box sections[J]. Journal of Constructional Steel Research, 2011, 67(6): 929-935. DOI:10.1016/j.jcsr.2011.02.003.
[5] Georgieva I, Schueremans L, Vandewalle L, et al. Design of built-up cold-formed steel columns according to the direct strength method[J]. Procedia Engineering, 2012, 40: 119-124. DOI:10.1016/j.proeng.2012.07.066.
[6] Biggs K A, Ramseyer C, Ree S, et al. Experimental testing of cold-formed built-up members in pure compression[J]. Steel and Composite Structures, 2015, 18(6): 1331-1351. DOI:10.12989/scs.2015.18.6.1331.
[7] Zhang J H, Young B. Numerical investigation and design of cold-formed steel built-up open section columns with longitudinal stiffeners[J]. Thin-Walled Structures, 2015, 89: 178-191. DOI:10.1016/j.tws.2014.12.011.
[8] Dabaon M, Ellobody E, Ramzy K. Experimental investigation of built-up cold-formed steel section battened columns[J]. Thin-Walled Structures, 2015, 92: 137-145. DOI:10.1016/j.tws.2015.03.001.
[9] Li Y Q, Li Y L, Wang S K, et al. Ultimate load-carrying capacity of cold-formed thin-walled columns with built-up box and I section under axial compression[J]. Thin-Walled Structures, 2014, 79: 202-217. DOI:10.1016/j.tws.2014.02.003.
[10] 李元齐, 刘翔, 沈祖炎, 等. 高强冷弯薄壁型钢卷边槽形截面偏压构件试验研究及承载力分析[J]. 建筑结构学报, 2010, 31(11): 26-35. DOI:10.14006/j.jzjgxb.2010.11.003.
Li Y Q, Liu X, Shen Z Y, et al. Experimental study and load-carrying capacity analysis of eccentrically-compressed high-strength cold-formed thin-walled steel lipped channel columns[J]. Journal of Building Structures, 2010, 31(11): 26-35. DOI:10.14006/j.jzjgxb.2010.11.004. (in Chinese)
[11] 周绪红, 李喆, 刘永健, 等. 冷弯薄壁型钢拼合截面柱轴压承载力计算[J]. 建筑科学与工程学报, 2012, 29(4): 1-6. DOI: 10.3969/j.issn.1673-2049.2012. 04.001.
Zhou X H, Li Z, Liu Y J, et al. Calculation method for bearing capacity of cold-formed steel built-up columns under axial compression[J]. Journal of Architecture and Civil Engineering, 2012, 29(4): 1-6. DOI:10.3969/j.issn.1673-2049.2012.04. 001. (in Chinese)
[12] 聂少锋, 霍洋洋, 周天华, 等. 冷弯薄壁型钢四肢拼合箱形柱偏压受力性能试验研究与数值分析[J]. 土木工程学报, 2016, 49(10): 1-10,17. DOI:10.15951/j.tmgcxb.2016.10.003.
Nie S F, Huo Y Y, Zhou T H, et al. Experimental study and numerical analysis on cold-formed thin-walled quadruple-limb built-up box-section columns under eccentric compression[J]. China Civil Engineering Journal, 2016, 49(10): 1-10,17. DOI:10.15951/j.tmgcxb.2016.10.003. (in Chinese)
[13] 聂少锋, 周天华, 周绪红, 等. 双肢冷弯薄壁型钢拼合箱形柱受压试验研究与有限元分析[J]. 建筑结构学报, 2017, 38(10): 10-20. DOI:10.14006/j.jzjgxb.2017.10.002.
Nie S F, Zhou T H, Zhou X H, et al. Experimental study and numerical analysis on double limb cold-formed steel built-up closed section columns under compression[J]. Journal of Building Structures, 2017, 38(10): 10-20. DOI:10.14006/j.jzjgxb.2017.10.002. (in Chinese)
[14] 左小雨. 冷弯薄壁型钢三肢闭合箱形拼合柱受压受力性能研究[D]. 西安: 长安大学, 2016.
  Zuo X Y. Research on the axially compressed behavior of triple-limbs box section built-up cold-formed steel columns[D]. Xi’an:Chang’an University, 2016.(in Chinese)
[15] 中华人民共和国住房和城乡建设部. GB/T 228.1—2010 金属材料拉伸试验: 第1部分: 室温试验方法[S]. 北京: 中国标准出版社, 2010.

备注/Memo

备注/Memo:
收稿日期: 2018-06-06.
作者简介: 聂少锋(1981—),男,博士,副教授,niesf126@126.com.
基金项目: 国家重点研发计划资助项目(2016YFC0701201)、国家自然科学基金资助项目(51878055)、陕西省工业攻关资助项目(2014K06-23).
引用本文: 聂少锋,周天华,周绪红,等.三肢冷弯薄壁型钢拼合双腔箱形柱受压性能试验研究与数值分析[J].东南大学学报(自然科学版),2019,49(1):25-33. DOI:10.3969/j.issn.1001-0505.2019.01.004.
更新日期/Last Update: 2019-01-20